7-8 Troubleshooting

On-screen error message

Recommended action

0B83 BMC IBF or OBF check

1.

Take one of the following measures to reboot (reset) the

 

failed

 

modular server.

 

 

 

* Issue an OS command.

 

 

 

* Press Ctrl + Alt + Del.

 

 

 

* Issue a command from Web browser of EXPRESSSCOPE

 

 

 

Engine or NEC ESMPRO Manager.

 

 

2.

Take one of the following measures to power off the modular

 

 

 

server and then on.

 

 

 

* Power off the modular server from OS, then press the

 

 

 

POWER/SLEEP switch to power on.

 

 

 

* Press the POWER/SLEEP switch to power off the modular

 

 

 

server, then press it again to power on.

 

 

 

* Issue a command from Web browser of EXPRESSSCOPE

 

 

 

Engine or NEC ESMPRO Manager.

 

 

3.

Power off the modular server by issuing an OS command or

 

 

 

press the POWER/SLEEP switch. Take the modular server

 

 

 

out of the Module Enclosure, and install it again. Then, press

 

 

 

the POWER/SLEEP switch to turn on the modular server.

 

 

4.

If the same error persists, contact your service representative.

0B8A

BMC SEL area full

1.

Run BIOS SETUP, select [Server] - [Event Log Configuration]

 

 

 

- [Clear All Error Logs] to clear the IPMI system event logs.

 

 

2.

If the same error persists, contact your service representative.

 

 

Note: You can make a backup copy of IPMI system event logs

 

 

 

through the Off-line Maintenance Utility before clearing the

 

 

 

IPMI system event logs on BIOS SETUP.

0B8B

BMC progress check

1.

Take one of the following measures to reboot (reset) the

 

timeout

 

modular server.

0B8D Could not redirect the

 

* Issue an OS command.

 

console - BMC Busy -

 

* Press Ctrl + Alt + Del.

0B8E Could not redirect the

 

* Issue a command from Web browser of EXPRESSSCOPE

 

console - BMC Error -

 

Engine or NEC ESMPRO Manager.

0B8F Could not redirect the

2.

Take one of the following measures to power off the modular

 

console - BMC Parameter

 

server and then on.

 

Error -

 

* Power off the modular server from OS, then press the

 

 

 

POWER/SLEEP switch to power on.

 

 

 

* Press the POWER/SLEEP switch to power off the modular

 

 

 

server, then press it again to power on.

 

 

 

* Issue a command from Web browser of EXPRESSSCOPE

 

 

 

Engine or NEC ESMPRO Manager.

 

 

3.

Power off the modular server by issuing an OS command or

 

 

 

press the POWER/SLEEP switch. Take the modular server

 

 

 

out of the Module Enclosure, and install it again. Then, press

 

 

 

the POWER/SLEEP switch to turn on the modular server.

 

 

4.

If the same error persists, contact your service representative.