Recommended action | |||
0B83 BMC IBF or OBF check | 1. | Take one of the following measures to reboot (reset) the | |
| failed |
| modular server. |
|
|
| * Issue an OS command. |
|
|
| * Press Ctrl + Alt + Del. |
|
|
| * Issue a command from Web browser of EXPRESSSCOPE |
|
|
| Engine or NEC ESMPRO Manager. |
|
| 2. | Take one of the following measures to power off the modular |
|
|
| server and then on. |
|
|
| * Power off the modular server from OS, then press the |
|
|
| POWER/SLEEP switch to power on. |
|
|
| * Press the POWER/SLEEP switch to power off the modular |
|
|
| server, then press it again to power on. |
|
|
| * Issue a command from Web browser of EXPRESSSCOPE |
|
|
| Engine or NEC ESMPRO Manager. |
|
| 3. | Power off the modular server by issuing an OS command or |
|
|
| press the POWER/SLEEP switch. Take the modular server |
|
|
| out of the Module Enclosure, and install it again. Then, press |
|
|
| the POWER/SLEEP switch to turn on the modular server. |
|
| 4. | If the same error persists, contact your service representative. |
0B8A | BMC SEL area full | 1. | Run BIOS SETUP, select [Server] - [Event Log Configuration] |
|
|
| - [Clear All Error Logs] to clear the IPMI system event logs. |
|
| 2. | If the same error persists, contact your service representative. |
|
| Note: You can make a backup copy of IPMI system event logs | |
|
|
| through the |
|
|
| IPMI system event logs on BIOS SETUP. |
0B8B | BMC progress check | 1. | Take one of the following measures to reboot (reset) the |
| timeout |
| modular server. |
0B8D Could not redirect the |
| * Issue an OS command. | |
| console - BMC Busy - |
| * Press Ctrl + Alt + Del. |
0B8E Could not redirect the |
| * Issue a command from Web browser of EXPRESSSCOPE | |
| console - BMC Error - |
| Engine or NEC ESMPRO Manager. |
0B8F Could not redirect the | 2. | Take one of the following measures to power off the modular | |
| console - BMC Parameter |
| server and then on. |
| Error - |
| * Power off the modular server from OS, then press the |
|
|
| POWER/SLEEP switch to power on. |
|
|
| * Press the POWER/SLEEP switch to power off the modular |
|
|
| server, then press it again to power on. |
|
|
| * Issue a command from Web browser of EXPRESSSCOPE |
|
|
| Engine or NEC ESMPRO Manager. |
|
| 3. | Power off the modular server by issuing an OS command or |
|
|
| press the POWER/SLEEP switch. Take the modular server |
|
|
| out of the Module Enclosure, and install it again. Then, press |
|
|
| the POWER/SLEEP switch to turn on the modular server. |
|
| 4. | If the same error persists, contact your service representative. |