Troubleshooting 7-5

 

 

 

 

 

 

 

On-screen error message

Recommended action

 

0250 System battery is dead -

1.

Take one of the following measures to power off the modular

 

 

Replace and run SETUP

 

server and then on.

 

 

 

 

* Power off the modular server from OS, then press the

 

 

 

 

POWER/SLEEP switch to power on.

 

 

 

 

* Press the POWER/SLEEP switch to power off the modular

 

 

 

 

server, then press it again to power on.

 

 

 

 

* Issue a command from Web browser of EXPRESSSCOPE

 

 

 

 

Engine or NEC ESMPRO Manager.

 

 

 

2.

Power off the modular server by issuing an OS command or

 

 

 

 

press the POWER/SLEEP switch. Take the modular server

 

 

 

 

out of the Module Enclosure, and install it again. Then, press

 

 

 

 

the POWER/SLEEP switch to turn on the modular server.

 

 

 

3.

Check installation status of the lithium battery on modular

 

 

 

 

server.

 

 

 

4.

If the same error persists, contact your service representative.

 

 

 

Note: Restart the modular server, run BIOS SETUP, and provide

 

 

 

 

settings for date, time, and others.

 

0251

System CMOS checksum

The default configuration of BIOS SETUP is used.

 

 

bad - Default configuration

1.

Run the BIOS SETUP utility to correct the setting.

 

 

used

2.

If the same error persists, contact your service representative.

 

0252

Password checksum bad -

The password has been cleared.

 

 

Passwords cleared

1.

Run the BIOS SETUP utility to correct the setting.

 

 

 

2.

If the same error persists, contact your service representative.

 

0260

System timer error

1.

Take one of the following measures to power off the modular

 

0270

Real timer error

 

server and then on.

 

 

 

 

* Power off the modular server from OS, then press the

 

 

 

 

POWER/SLEEP switch to power on.

 

 

 

 

* Press the POWER/SLEEP switch to power off the modular

 

 

 

 

server, then press it again to power on.

 

 

 

 

* Issue a command from Web browser of EXPRESSSCOPE

 

 

 

 

Engine or NEC ESMPRO Manager.

 

 

 

2.

If the same error persists, contact your service representative.

 

0271 Check date and time

1.

Run the BIOS SETUP utility to set the current date and time.

 

 

setting

2.

If the same error persists, contact your service representative.

 

02D0

 

1.

Take one of the following measures to reboot (reset) the

 

 

 

 

modular server.

 

 

 

 

* Issue an OS command.

 

 

 

 

* Press Ctrl + Alt + Del.

 

 

 

 

* Issue a command from Web browser of EXPRESSSCOPE

 

 

 

 

Engine or NEC ESMPRO Manager.

 

 

 

2.

Take one of the following measures to power off the modular

 

 

 

 

server and then on.

 

 

 

 

* Power off the modular server from OS, then press the

 

 

 

 

POWER/SLEEP switch to power on.

 

 

 

 

* Press the POWER/SLEEP switch to power off the modular

 

 

 

 

server, then press it again to power on.

 

 

 

 

* Issue a command from Web browser of EXPRESSSCOPE

 

 

 

 

Engine or NEC ESMPRO Manager.

 

 

 

3.

If the same error persists, contact your service representative.