Troubleshooting
When STATUS lamp is lighting in amber:
Description | Action | |||
message | ||||
|
|
| ||
Proc Temp Alm 02 | A low temperature alarm | 1. | Check if fans in Module Enclosure work | |
| is detected in processor. |
| normally. | |
Proc Temp Alm 09 | A high temperature alarm | 2. | Refer to the User’s Guide of the Module | |
| is detected in processor. |
| Enclosure to make sure that the sufficient | |
|
|
| number of fans are installed in correct | |
|
|
| locations. | |
|
| 3. | Check if the fans and modular servers are | |
|
|
| installed in correct locations. | |
|
| 4. | Check installation status of the heat sink of | |
|
|
| the modular server. | |
|
| 5. | Check if the operating environment satisfies | |
|
|
| the required guaranteed temperature. | |
|
| 6. | Take one of the following measures to | |
|
|
| reboot (reset) the modular server. | |
|
|
| * Issue an OS command. | |
|
|
| * Press Ctrl + Alt + Del. | |
|
|
| * Issue a command from Web browser of | |
|
|
| EXPRESSSCOPE Engine or NEC | |
|
|
| ESMPRO Manager. | |
|
| 7. | Take one of the following measures to power | |
|
|
| off the modular server and then on. | |
|
|
| * Power off the modular server from OS, | |
|
|
| then press the POWER/SLEEP switch to | |
|
|
| power on. | |
|
|
| * Press the POWER/SLEEP switch to power | |
|
|
| off the modular server, then press it again | |
|
|
| to power on. | |
|
|
| * Issue a command from Web browser of | |
|
|
| EXPRESSSCOPE Engine or NEC | |
|
|
| ESMPRO Manager. | |
|
| 8. | Power off the modular server by issuing an | |
|
|
| OS command or press the POWER/SLEEP | |
|
|
| switch. Take the modular server out of the | |
|
|
| Module Enclosure, and install it again. Then, | |
|
|
| press the POWER/SLEEP switch to turn on | |
|
|
| the modular server. | |
|
| 9. | If the same error persists, contact your | |
|
|
| service representative. |