When STATUS lamp is blinking in amber:
Description | Action | |||
message | ||||
|
|
| ||
System FAN2R Alm | A warning was detected | 1. | Refer to the User’s Guide of the Module | |
| on the rear fan box 2. |
| Enclosure to replace the fan unit. | |
System FAN2F Alm | A warning was detected | 2. | If the same error persists, contact your | |
| on the front fan box 2. |
| service representative. | |
System FAN1R Alm | A warning was detected |
|
| |
| on the rear fan box 1. |
|
| |
System FAN1F Alm | A warning was detected |
|
| |
| on the front fan box 1. |
|
| |
Proc Temp Alm 00 | A low temperature | 1. | Check if fans in Module Enclosure work | |
| warning was detected on |
| normally. | |
| processor. | 2. | Refer to the User’s Guide of the Module | |
Proc Temp Alm 07 | A high temperature |
| Enclosure to make sure that the sufficient | |
| warning was detected on |
| number of fans are installed in correct | |
| processor. |
| locations. | |
|
| 3. | Check if the fans and modular servers are | |
|
|
| installed in correct locations. | |
|
| 4. | Check installation status of the heat sink of | |
|
|
| the modular server. | |
|
| 5. Check if the ambient temperature of | ||
|
|
| installation location satisfies the operation | |
|
|
| guarantee condition. | |
|
| 6. Take one of the following measures to | ||
|
|
| reboot (reset) the modular server. | |
|
|
| * Issue an OS command. | |
|
|
| * Press Ctrl + Alt + Del. | |
|
|
| * Issue a command from Web browser of | |
|
|
| EXPRESSSCOPE Engine or NEC | |
|
|
| ESMPRO Manager. | |
|
| 7. Take one of the following measures to power | ||
|
|
| off the modular server and then on. | |
|
|
| * Power off the modular server from OS, | |
|
|
| then press the POWER/SLEEP switch to | |
|
|
| power on. | |
|
|
| * Press the POWER/SLEEP switch to power | |
|
|
| off the modular server, then press it again | |
|
|
| to power on. | |
|
|
| * Issue a command from Web browser of | |
|
|
| EXPRESSSCOPE Engine or NEC | |
|
|
| ESMPRO Manager. | |
|
| 8. Power off the modular server by issuing an | ||
|
|
| OS command or press the POWER/SLEEP | |
|
|
| switch. Take the modular server out of the | |
|
|
| Module Enclosure, and install it again. Then, | |
|
|
| press the POWER/SLEEP switch to turn on | |
|
|
| the modular server. | |
|
| 9. If the same error persists, contact your | ||
|
|
| service representative. |