Description | Action | ||
message | |||
|
| ||
WDT Timeout | Watchdog timer timeout | 1. Take one of the following measures to | |
| error occurred. | reboot (reset) the modular server. | |
|
| * Issue an OS command. | |
|
| * Press Ctrl + Alt + Del. | |
|
| * Issue a command from Web browser of | |
|
| EXPRESSSCOPE Engine or NEC | |
|
| ESMPRO Manager. | |
|
| 2. Take one of the following measures to power | |
|
| off the modular server and then on. | |
|
| * Power off the modular server from OS, | |
|
| then press the POWER/SLEEP switch to | |
|
| power on. | |
|
| * Press the POWER/SLEEP switch to power | |
|
| off the modular server, then press it again | |
|
| to power on. | |
|
| * Issue a command from Web browser of | |
|
| EXPRESSSCOPE Engine or NEC | |
|
| ESMPRO Manager. | |
|
| 3. Power off the modular server by issuing a | |
|
| command from OS or pressing the | |
|
| POWER/SLEEP switch. Remove the | |
|
| modular server from Module Enclosure, then | |
|
| install it again. Then press the | |
|
| POWER/SLEEP switch to power on the | |
|
| modular server. | |
|
| 4. If the same error persists, contact your | |
|
| service representative. | |
Processor | Forced | 1. Take one of the following measures to power | |
| occurred due to a thermal | on the modular server and then on. | |
| error in processor. | * Press the POWER/SLEEP switch to power | |
|
| on. | |
|
| * Issue a command from Web browser of | |
|
| EXPRESSSCOPE Engine or NEC | |
|
| ESMPRO Manager. | |
|
| 2. Check if fans in Module Enclosure work | |
|
| normally. | |
|
| 3. Refer to the User’s Guide of the Module | |
|
| Enclosure to make sure that the sufficient | |
|
| number of fans are installed in correct | |
|
| locations. | |
|
| 4. Check if the fans and modular servers are | |
|
| installed in correct locations. | |
|
| 5. Check if the ambient temperature of | |
|
| installation location satisfies the operation | |
|
| guarantee condition. | |
|
| 6. If the same error persists, contact your | |
|
| service representative. |