Troubleshooting |
|
| ||
|
|
| ||
|
|
| ||
| Recommended action | |||
| 0B70 The error occurred during | 1. | Take one of the following measures to reboot (reset) the | |
|
| temperature sensor |
| modular server. |
|
| reading |
| * Issue an OS command. |
|
|
|
| * Press Ctrl + Alt + Del. |
|
|
|
| * Issue a command from Web browser of EXPRESSSCOPE |
|
|
|
| Engine or NEC ESMPRO Manager. |
|
|
| 2. | Take one of the following measures to power off the modular |
|
|
|
| server and then on. |
|
|
|
| * Power off the modular server from OS, then press the |
|
|
|
| POWER/SLEEP switch to power on. |
|
|
|
| * Press the POWER/SLEEP switch to power off the modular |
|
|
|
| server, then press it again to power on. |
|
|
|
| * Issue a command from Web browser of EXPRESSSCOPE |
|
|
|
| Engine or NEC ESMPRO Manager. |
|
|
| 3. | Power off the modular server by issuing an OS command or |
|
|
|
| press the POWER/SLEEP switch. Take the modular server |
|
|
|
| out of the Module Enclosure, and install it again. Then, press |
|
|
|
| the POWER/SLEEP switch to turn on the modular server. |
|
|
| 4. | If the same error persists, contact your service representative. |
| 0B71 | System Temperature out | 1. | Check if fans in Module Enclosure work normally. |
|
| of the range | 2. | Refer to the User’s Guide of the Module Enclosure to make |
|
|
|
| sure that the sufficient number of fans are installed in correct |
|
|
|
| locations. |
|
|
| 3. | Check if the fans and modular servers are installed in correct |
|
|
|
| locations. |
|
|
| 4. | Check installation status of heat sink of the modular server. |
|
|
| 5. | Check if the ambient temperature of installation location |
|
|
|
| satisfies the operation guarantee condition. |
|
|
| 6. | Take one of the following measures to reboot (reset) the |
|
|
|
| modular server. |
|
|
|
| * Issue an OS command. |
|
|
|
| * Press Ctrl + Alt + Del. |
|
|
|
| * Issue a command from Web browser of EXPRESSSCOPE |
|
|
|
| Engine or NEC ESMPRO Manager. |
|
|
| 7. | Take one of the following measures to power off the modular |
|
|
|
| server and then on. |
|
|
|
| * Power off the modular server from OS, then press the |
|
|
|
| POWER/SLEEP switch to power on. |
|
|
|
| * Press the POWER/SLEEP switch to power off the modular |
|
|
|
| server, then press it again to power on. |
|
|
|
| * Issue a command from Web browser of EXPRESSSCOPE |
|
|
|
| Engine or NEC ESMPRO Manager. |
|
|
| 8. | Power off the modular server by issuing an OS command or |
|
|
|
| press the POWER/SLEEP switch. Take the modular server |
|
|
|
| out of the Module Enclosure, and install it again. Then, press |
|
|
|
| the POWER/SLEEP switch to turn on the modular server. |
|
|
| 9. | If the same error persists, contact your service |
|
|
|
| representative. |