Description | Action | ||
message | |||
|
| ||
BB Temp2 Alm 02 | A low temperature alarm | 1. Check if fans in Module Enclosure work | |
| is detected in base board. | normally. | |
BB Temp2 Alm 09 | A high temperature alarm | 2. Refer to the User’s Guide of the Module | |
| is detected in base board. | Enclosure to make sure that the sufficient | |
BB Temp1 Alm 02 | A low temperature alarm | number of fans are installed in correct | |
| is detected in base board. | locations. | |
BB Temp1 Alm 09 | A high temperature alarm | 3. Check if the fans and modular servers are | |
| is detected in base board. | installed in correct locations. | |
|
| 4. Check if the ambient temperature of | |
|
| installation location satisfies the operation | |
|
| guarantee condition. | |
|
| 5. Take one of the following measures to | |
|
| reboot (reset) the modular server. | |
|
| * Issue an OS command. | |
|
| * Press Ctrl + Alt + Del. | |
|
| * Issue a command from Web browser of | |
|
| EXPRESSSCOPE Engine or NEC | |
|
| ESMPRO Manager. | |
|
| 6. Take one of the following measures to power | |
|
| off the modular server and then on. | |
|
| * Power off the modular server from OS, | |
|
| then press the POWER/SLEEP switch to | |
|
| power on. | |
|
| * Press the POWER/SLEEP switch to power | |
|
| off the modular server, then press it again | |
|
| to power on. | |
|
| * Issue a command from Web browser of | |
|
| EXPRESSSCOPE Engine or NEC | |
|
| ESMPRO Manager. | |
|
| 7. Power off the modular server by issuing an | |
|
| OS command or press the POWER/SLEEP | |
|
| switch. Take the modular server out of the | |
|
| Module Enclosure, and install it again. Then, | |
|
| press the POWER/SLEEP switch to turn on | |
|
| the modular server. | |
|
| 8. If the same error persists, contact your | |
|
| service representative. |