7-26 Troubleshooting

On-screen

Description

Action

message

 

 

Proc 1.05v Alm 00

1.05V voltage warning

1. Take one of the following measures to power

 

(lower limit) was detected

off the modular server and then on.

 

on processor.

* Power off the modular server from OS,

Proc 1.05v Alm 07

1.05V voltage warning

then press the POWER/SLEEP switch to

 

(upper limit) was detected

power on.

 

on processor.

* Press the POWER/SLEEP switch to power

Proc Core Alm 00

A core voltage warning

off the modular server, then press it again

 

(lower limit) was detected

to power on.

 

on processor.

* Issue a command from Web browser of

Proc Core Alm 07

A core voltage warning

EXPRESSSCOPE Engine or NEC

 

(upper limit) was detected

ESMPRO Manager.

 

on processor.

2. Power off the modular server by issuing an

 

 

OS command or press the POWER/SLEEP

 

 

switch. Take the modular server out of the

 

 

Module Enclosure, and install it again. Then,

 

 

press the POWER/SLEEP switch to turn on

 

 

the modular server.

 

 

3. Check installation status of the heat sink of

 

 

the modular server.

 

 

4. If the same error persists, contact your

 

 

service representative.