Troubleshooting
Description | Action | ||
message | |||
|
| ||
VBAT Alm 02 | A voltage alarm (lower | 1. Take one of the following measures to power | |
| limit) occurred on lithium | off the modular server and then on. | |
| battery. | * Power off the modular server from OS, | |
VBAT Alm 09 | A voltage alarm (upper | then press the POWER/SLEEP switch to | |
| limit) occurred on lithium | power on. | |
| battery. | * Press the POWER/SLEEP switch to power | |
|
| off the modular server, then press it again | |
|
| to power on. | |
|
| * Issue a command from Web browser of | |
|
| EXPRESSSCOPE Engine or NEC | |
|
| ESMPRO Manager. | |
|
| 2. Power off the modular server by issuing an | |
|
| OS command or press the POWER/SLEEP | |
|
| switch. Take the modular server out of the | |
|
| Module Enclosure, and install it again. Then, | |
|
| press the POWER/SLEEP switch to turn on | |
|
| the modular server. | |
|
| 3. Check installation status of the lithium | |
|
| battery mounted on modular server. | |
|
| 4. If the same error persists, contact your | |
|
| service representative. |