Option | Parameter | Description | Your Setting |
Thermal Sensor | Disabled | Specify whether the temperature |
|
| [Enabled] | sensor monitoring feature is |
|
|
| enabled or disabled. If a thermal |
|
|
| error is detected with this item |
|
|
| being set to "Enabled", the system |
|
|
| stops at the end of POST. |
|
BMC IRQ | Disabled | Specify whether to assign IRQ for |
|
| [IRQ 11] | BMC (Baseboard Management |
|
|
| Controller). |
|
Post Error Pause | Disabled | Specify whether POST is aborted |
|
| [Enabled] | once at the end of POST if an error |
|
|
| occurs during the execution of |
|
|
| POST. |
|
Specify the |
| ||
| Stay Off | Shows the system status when the |
|
| [Last State] | AC power is supplied again to the |
|
| Power On | modular server. See the table |
|
|
| below. |
|
Power ON Delay | Default [t1] (s) | Specify the |
|
Time | between 1 and 255 seconds. This |
| |
|
| option is available only when |
|
|
| "Power On" or "Last State" is |
|
|
| specified for AC LINK. |
|
Platform Event | Disabled | Specify whether the Platform |
|
Filtering | [Enabled] | Event Filtering feature of the |
|
|
| Baseboard Management |
|
|
| Controller (BMC) is enabled or |
|
|
| disabled. |
|
|
| [ | ]: |
The table below shows the operation when the AC power to the modular server is turn off once and then on again, depending on the setting of
System status before AC power off | Setting of |
| ||
Stay Off | Last State | Power On | ||
| ||||
Operating | Off | On | On | |
Aborting (DC power being off also) | Off | Off | On | |
Forced shutdown* | Off | Off | On |
*Press the POWER/SLEEP switch continuously for four seconds or longer. This forcibly turns off the power.