Description | Action | ||
message | |||
|
| ||
BB 1.8v Alm 02 | 1.8V voltage alarm (lower | 1. Take one of the following measures to power | |
| limit) occurred. | off the modular server and then on. | |
BB 1.8v Alm 09 | 1.8V voltage alarm (upper | * Power off the modular server from OS, | |
| limit) occurred. | then press the POWER/SLEEP switch to | |
BB 0.9v Alm 02 | 0.9V voltage alarm (lower | power on. | |
| limit) occurred. | * Press the POWER/SLEEP switch to power | |
BB 0.9v Alm 09 | 0.9V voltage alarm (upper | off the modular server, then press it again | |
| limit) occurred. | to power on. | |
BB 1.5v Alm 02 | 1.5V voltage alarm (lower | * Issue a command from Web browser of | |
EXPRESSSCOPE Engine or NEC | |||
| limit) occurred. | ||
| ESMPRO Manager. | ||
BB 1.5v Alm 09 | 1.5V voltage alarm (upper | ||
2. Power off the modular server by issuing an | |||
| limit) occurred. | ||
| OS command or press the POWER/SLEEP | ||
BB 3.3v Alm 02 | 3.3V voltage alarm (lower | ||
switch. Take the modular server out of the | |||
| limit) occurred. | ||
| Module Enclosure, and install it again. Then, | ||
BB 3.3v Alm 09 | 3.3V voltage alarm (upper | ||
press the POWER/SLEEP switch to turn on | |||
| limit) occurred. | ||
| the modular server. | ||
BB 5.0v Alm 02 | 5.0V voltage alarm (lower | ||
3. If the same error persists, contact your | |||
| limit) occurred. | ||
| service representative. | ||
BB 5.0v Alm 09 | 5.0V voltage alarm (upper | ||
| |||
| limit) occurred. |
| |
BB 12v Alm 02 | 12V voltage alarm (lower |
| |
| limit) occurred. |
| |
BB 12v Alm 09 | 12V voltage alarm (upper |
| |
| limit) occurred. |
| |
BB 1.2vsb Alm 02 | 1.2Vsb voltage alarm |
| |
| (lower limit) occurred. |
| |
BB 1.2vsb Alm 09 | 1.2Vsb voltage alarm |
| |
| (upper limit) occurred. |
| |
BB 3.3vsb Alm 02 | 3.3Vsb voltage alarm |
| |
| (lower limit) occurred. |
|
BB3.3vsb Alm 09 3.3Vsb voltage alarm (upper limit) occurred.