7-20 Troubleshooting

On-screen

Description

Action

message

 

 

BB 1.8v Alm 02

1.8V voltage alarm (lower

1. Take one of the following measures to power

 

limit) occurred.

off the modular server and then on.

BB 1.8v Alm 09

1.8V voltage alarm (upper

* Power off the modular server from OS,

 

limit) occurred.

then press the POWER/SLEEP switch to

BB 0.9v Alm 02

0.9V voltage alarm (lower

power on.

 

limit) occurred.

* Press the POWER/SLEEP switch to power

BB 0.9v Alm 09

0.9V voltage alarm (upper

off the modular server, then press it again

 

limit) occurred.

to power on.

BB 1.5v Alm 02

1.5V voltage alarm (lower

* Issue a command from Web browser of

EXPRESSSCOPE Engine or NEC

 

limit) occurred.

 

ESMPRO Manager.

BB 1.5v Alm 09

1.5V voltage alarm (upper

2. Power off the modular server by issuing an

 

limit) occurred.

 

OS command or press the POWER/SLEEP

BB 3.3v Alm 02

3.3V voltage alarm (lower

switch. Take the modular server out of the

 

limit) occurred.

 

Module Enclosure, and install it again. Then,

BB 3.3v Alm 09

3.3V voltage alarm (upper

press the POWER/SLEEP switch to turn on

 

limit) occurred.

 

the modular server.

BB 5.0v Alm 02

5.0V voltage alarm (lower

3. If the same error persists, contact your

 

limit) occurred.

 

service representative.

BB 5.0v Alm 09

5.0V voltage alarm (upper

 

 

limit) occurred.

 

BB 12v Alm 02

12V voltage alarm (lower

 

 

limit) occurred.

 

BB 12v Alm 09

12V voltage alarm (upper

 

 

limit) occurred.

 

BB 1.2vsb Alm 02

1.2Vsb voltage alarm

 

 

(lower limit) occurred.

 

BB 1.2vsb Alm 09

1.2Vsb voltage alarm

 

 

(upper limit) occurred.

 

BB 3.3vsb Alm 02

3.3Vsb voltage alarm

 

 

(lower limit) occurred.

 

BB3.3vsb Alm 09 3.3Vsb voltage alarm (upper limit) occurred.