Installing the firmware upgrades 107
Procedure Steps
Step Action
1Load the hard drive firmware upgrade CD into the
2Log on to the server as the SSA role (ntsysadm).
3Reboot the server. sudo reboot
4If the operating system has been installed, change the boot sequence so that the
•When the BIOS information appears, press F12 to select the boot sequence.
•Select
Otherwise, wait for the server to reboot.
The ServeRAID Manager Hard Drive Update screen appears.
5If an upgrade is required, press Enter to apply the upgrade. The hard drive firmware upgrade is installed.
Otherwise, press Enter and go to step 7.
6Select OK twice to complete the upgrade.
Attention: Do not power off the system during the upgrade.
7When the update completes, remove the CD from the
Installing ServeRAID firmware upgrades
Use this procedure to install ServeRAID firmware upgrades. This procedure requires the reboot of the server.
Prerequisites
•You must be assigned to the SSA role (ntsysadm).
•You must have the CD containing the ServeRAID firmware upgrade file.
Application Server 5300
Nortel AS 5300 Installation
4 November 2008