Installing the firmware upgrades 107

Procedure Steps

Step Action

1Load the hard drive firmware upgrade CD into the CD-ROM drive.

2Log on to the server as the SSA role (ntsysadm).

3Reboot the server. sudo reboot

4If the operating system has been installed, change the boot sequence so that the CD-ROM is the primary boot device by doing the following:

When the BIOS information appears, press F12 to select the boot sequence.

Select CD-ROMas the primary boot device.

Otherwise, wait for the server to reboot.

The ServeRAID Manager Hard Drive Update screen appears.

5If an upgrade is required, press Enter to apply the upgrade. The hard drive firmware upgrade is installed.

Otherwise, press Enter and go to step 7.

6Select OK twice to complete the upgrade.

Attention: Do not power off the system during the upgrade.

7When the update completes, remove the CD from the CD-ROM drive and select OK to boot the operating system.

--End--

Installing ServeRAID firmware upgrades

Use this procedure to install ServeRAID firmware upgrades. This procedure requires the reboot of the server.

Prerequisites

You must be assigned to the SSA role (ntsysadm).

You must have the CD containing the ServeRAID firmware upgrade file.

Application Server 5300

Nortel AS 5300 Installation

NN42040-300 01.04

4 November 2008