80 Patches

Network Element

Client impact

Subscriber impact

 

 

 

 

is transferred to the Accounting

 

 

Manager and no information is

 

 

lost.

 

 

 

 

Provisioning

The Provisioning Manager is

While a Provisioning Manager is being

Managers

not deployed with redundant

patched, users from the Domain URL

 

instances. There is no user

corresponding to the Provisioning

 

access to the Provisioning Client

Manager being patched will be able

 

during upgrade.

to login and make calls; however,

 

 

downloading of the service package

 

 

is not possible. Once the Provisioning

 

 

Manager is patched successfully,

 

 

subsequent logins will be successful.

 

 

If the optional Personal Agent Manager

 

 

is configured, there is no impact when

 

 

patching the Provisioning Manager. If

 

 

Personal Agent services are provided by

 

 

the Provisioning Manager that is being

 

 

patched, the subscriber is not able to

 

 

access the Personal Agent until the

 

 

patching process is completed.

 

 

Subscribers cannot perform click-to-call

 

 

dialing from the PC Client until the

 

 

patching process is completed.

 

 

 

Personal Agent

The Personal Agent Manager

Subscribers cannot perform click to call

Managers

is not deployed with redundant

dialing from the PC Client.

 

instances. There is no user

 

 

access to the Personal Agent

 

 

during upgrade.

 

 

 

 

Session Managers

If there are redundant instances

If there is only one configured Session

 

of the Session Manager, one

Manager Instance, no new calls will be

 

instance will be in active state

allowed on system until the Session

 

and one will be in hot standby

Manager instance is active again.

 

state.

 

 

 

 

IP Client Managers

More than one IPCM element

If there is only one IPCM on the system,

 

can be configured on the

Nortel Networks IP 2002/2004 phones

 

system. Each IPCM will contain

cannot connect and all service is lost.

 

only one instance. During

 

 

upgrade, the IPCM is not

 

 

accessible.

 

 

 

 

Attention: Patch the Network Elements in the order specified in the procedure. If a particular Network Element is not configured on the system, you can skip it and proceed to the next one.

Application Server 5300

Nortel AS 5300 Installation

NN42040-300 01.04

4 November 2008

Copyright © 2007-2008 Nortel Networks

Page 80
Image 80
Nortel Networks 53r 5300 00 manual Network Element Client impact Subscriber impact