Hardware configuration 33

with the correct memory configuration but not recognized by the system. If this happens, contact your next level of support before proceeding.

3Select Advanced Setup.

4Select RSA-II Settings.

5Select Restore RSA II Defaults.

Network settings for the RSA-II card are restored to factory defaults. Any existing network connections to the RSA-II Ethernet interface are disconnected and no further connections can be made until network settings are reconfigured.

When the reset to factory defaults is complete, the following message appears:

RSA II Defaults Loaded!

If data had been previously configured for the RSA-II card, that data appears.

6Press Enter.

7Press Esc until the top level menu of the planar BIOS setup utility appears.

8Select Load Default Settings. The following message appears:

Current settings will be changed to their default settings - Press Enter to continue.

9Press Enter.

The planar BIOS is restored to the factory defaults.

10Select Exit Setup.

11Select Yes, save and exit the Setup Utility and press Enter. The server reboots.

--End--

Resetting the ServeRAID BIOS to factory defaults