Image 23

Mount the hardware 23

Table 6

IBM x3550 hardware characteristics (cont’d.)

Item

Description

 

 

Server identification

x3550, Model 7978 AC1

 

 

CPU

2 x Quad-Core Intel Xeon processor E5420, 2.5GHz, 12 MB L2 cache,

 

1333MHz FSB, 80w

 

 

Memory

8 GB PC2-5300 CL5 ECC DDR2 Chipkill FB DIMM 667MHz

 

 

Disk

2 x 73 GB 3.5-inch SAS, 15000 RPM, hot swap; RAID-1 mirrored using

 

IBM ServeRAID 8k-l SAS controller (hardware RAID-1)

 

 

AC power

2 x 670W A/C Power Supply (redundant, hot-swap); 2.8m, 100-240V,

 

C13 to IEC 320-C14 (WW) rack power cable

 

 

DC power

2 x 670W D/C Power Supply (redundant; hot swap); 2.8m, 100-240V,

 

C13 to IEC 320-C14 (WW) rack power cable

 

 

Remote management

Remote Supervisor Adapter II (RSA-II) Slimline with external RJ-45

 

Ethernet port (internal PCI card)

 

 

Optical drive

DVD/CD-RW

 

 

Cooling

Two fans per CPU, one fan per power supply

 

 

Networking

2 x 10/100/1000 Mbps

 

 

Serial

COM1, DB-9

 

 

Rail kit

Pizarro (Nortel-specified)

 

 

Mount the hardware

The AS 5300 server requires the Pizzaro rail kit for rack-mount installations.

Mounting the server

Use this procedure to mount the physical server into a server rack.

Prerequisites

You require a Pizzaro rail kit for each IBM x3550 server being installed.

Procedure Steps

Step Action

1Adjust the rail kit to fit in the frame. To properly support the server, each rail must be mounted to the outside of the front and rear of the frame.

2Adjust the left and right rails by sliding the rear mounting bracket to fit the frame.

Application Server 5300

Nortel AS 5300 Installation

NN42040-300 01.04

4 November 2008