Installation / 23

Maximum power cabling distance (approximate)

Depending on the size of cable you are using, you should remember the maximum cabling distances allowed between the RPI and the base station.

Wire size

Single-pair

Double-pair

 

 

 

0.6 mm (22 AWG)

800 m (2,500 ft.)

1200 m (4,000 ft.)

 

 

 

0.5 mm (24 AWG)

500 m (1,500 ft.)

1000 m (3,000 ft.)

 

 

 

When using two power pairs, ensure they are connected with the same polarity.

RPI Connector Overview

The following illustration shows where the input and output connectors are located on the RPI connector board.

RPI connector board

OBIX1 OBIX2 OBIX3 OBIX4

OBIX9

OBIX10OBIX11OBIX12

OBIX5 OBIX6 OBIX7 OBIX8

OBIX13 OBIX14OBIX15OBIX16

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IBIX4 IBIX3IBIX2 IBIX2IBIX3 IBIX1

P0992639 01

Modular ICS Companion Installer Guide

Page 29
Image 29
Nortel Networks P0992639 01 manual RPI Connector Overview, Wire size Single-pair Double-pair