Nortel Networks P0992639 01 manual Utam key

Models: P0992639 01

1 144
Download 144 pages 60.53 Kb
Page 110
Image 110

104 / Troubleshooting

Example

Meaning

Possible causes and actions

display

 

 

 

 

 

UTAM key

System disabled

Common message for a new

req’d

 

installation, see Software keys (U.S.

 

 

only) on page 67. The only other time

 

 

this alarm should appear is if you are

 

 

rebuilding a system:

 

 

1. Enter a UTAM Activation Key. See

 

 

Software keys (U.S. only) on page

 

 

67.

 

 

2. Obtain a Regression Key. See

 

 

Obtaining a Regression Key (U.S.

 

 

only) on page 100.

 

 

 

UTAM test

System is disabled.

- Ensure there is power to the base

failed

This alarm appears

stations and RPI or plug-top power

 

only after a restart

supply

 

 

- Ensure that the location and

 

 

number of base stations is correct

 

 

- Ensure that there are at least four

 

 

terminals and base stations

 

 

- Ensure that there are sufficient

 

 

Radio Credits to support the number

 

 

of base stations you have connected

 

 

- Restart the system with the correct

 

 

system configuration.

 

 

-The system may require a UTAM

 

 

Recovery Key. See Obtaining a

 

 

Recovery Key on page 100 .

 

 

 

Modular ICS Companion Installer Guide

P0992639 01

Page 110
Image 110