24 / Installation

Output connections

Feed the output pairs in through the bottom of the RPI and route the pairs to the output connectors as shown in the following illustration. If only one pair is used for powering a base station, connect the power pair to -PWR(1) and +PWR(1). If two pairs are used to power a base station, connect one pair to -PWR(1) and +PWR(1), and the second pair to -PWR(2) and +PWR(2).

Ensure both pairs have the same polarity.

Connecting two power pairs with opposing polarities may damage the base station and RPI.

Output connector pinout

OBIXn

-PWR(1)

-PWR(2)

TCM

TCM

+PWR(2)

+PWR(1)

Input connections

Feed the TCM input pairs from the ICS distribution frame through the top of the RPI and route the pairs to the input connectors (IBIX1 to IBIX4) as shown in the following illustration. There may be fewer than 16 input pairs in any given RPI installation.

Modular ICS Companion Installer Guide

P0992639 01

Page 30
Image 30
Nortel Networks P0992639 01 manual Ensure both pairs have the same polarity