BASIC

This menu sets buttons available on the key panel in REMOTE mode, switches display of the CTL counter display between 12 and 24-hour clock display, sets superimposed display, character displays in superimposed display, SETUP-MENU and other displays, sets recording formats, sets the formats that can be added to the play list and sets the time of the internal clock.

* An underlined setting indicates an initial value.

 

Item

Setting

 

 

 

 

 

Settings and brief function description

FR

SUPER

FR

SUPER

No.

DISP.

No.

DISP.

 

 

 

 

 

 

 

 

0000

DIS

Restricts the number of buttons on the key panel that are available when the REMOTE/

 

 

0001

STOP

LOCAL switch is set to REMOTE.

001

LOCAL ENA

0002

ENA

0: No buttons are available.

 

 

 

 

1: Only the STOP button is available.

 

 

 

 

2: All buttons are available.

 

 

 

 

 

 

 

0000

±12h

Switches the CTL counter display between 12 and 24-hour clock display.

002

CTL DISP

0001

24h

0: 12-hour clock display

 

 

 

 

1: 24-hour clock display

 

 

 

 

 

 

 

0000

OFF

Specifies whether to display the remaining time or total time via the VIDEO MON

 

 

0001

2L

connector and via superimposed display of the LCD panel.

 

 

0002

1L

0: No display.

 

 

0003

R/TTL

1: Displays remaining media time on the second line.

 

 

 

 

2: Displays remaining media time on the first line.

 

 

 

 

3: Displays the remaining media time on the first line and total media time on the second

 

 

 

 

line.

 

 

 

 

NOTE:

003

REMAIN SEL

 

 

• These functions are not displayed when “2L” is selected and “TIME” is set in setup

 

 

menu No. 006 DISPLAY SEL.

 

 

 

 

 

 

 

 

• Total tape time is not displayed when “R/TTL” is selected and “TIME” is set in setup

 

 

 

 

menu No. 006 DISPLAY SEL.

 

 

 

 

• When setup menu No. 041 LOOP REC is set to ON, the remaining time is indicated

 

 

 

 

on the second line when a setting other than OFF is selected.

 

 

 

 

• When setup menu No. 040 VFR REC is set to ON, the remaining time is indicated on

 

 

 

 

the second line when a setting other than OFF is selected.

 

 

 

 

• When setup menu No.693 GAMMA SEL is set to a value other than OFF, the remaining

 

 

 

 

time is indicated on the second line when a setting other than OFF is selected.

 

 

 

 

 

 

 

0000

TIME

Specifies the output of the VIDEO MON connector or what is displayed in the

 

 

0001

T&STA

superimposed display of the LCD panel.

 

 

0002

T&S&M

Here, “data” indicates the CTL/TC/UB value selected with the COUNTER button.

 

 

0003

T&RT

0: Data only

 

 

0004

T&YMD

1: Data and operating status

 

 

0005

T&MDY

2: Data, operating status and mode

 

 

0006

T&DMY

3: Data and REC TIME

 

 

0007

T&UB

4: Data and REC DATE (year/ month/day)

 

 

0008

T&CTL

5: Data and REC DATE (month/day/year)

006

DISPLAY SEL

0009

T&T

6: Data and REC DATE (day/month/year)

 

 

7: Data and user bit

 

 

 

 

 

 

 

 

However, when UB is selected with the COUNTER button, the time code is indicated after

 

 

 

 

the user bit.

 

 

 

 

8: Data and CTL

 

 

 

 

However, when CTL is selected with the COUNTER button, the time code is indicated

 

 

 

 

after CTL data.

 

 

 

 

9: Data and time code

 

 

 

 

NOTE:

 

 

 

 

An error message appears in the superimposed display if a warning or error occurs

 

 

 

 

when T&S&M is selected.

 

 

 

 

 

120 Setup: Item Settings