OPERATION

This menu allows you to set method for engaging search dial operations, maximum shuttle speed operation, maximum speed of FF and REW operation, NEXT and PREV seek operations, display of warning messages when REF.VIDEO is not connected, PLAY delay time, battery type, display of warnings when power is too low, voltage when the power supply is turned off.

* An underlined setting indicates an initial value.

 

Item

Setting

 

 

 

 

 

 

 

Settings and brief function description

 

 

FR

SUPER

FR

SUPER

 

 

No.

DISP.

No.

DISP.

 

 

 

 

 

 

 

 

 

 

 

 

0000

DIAL

Specifies method for transferring to the search mode (search dial operation).

 

 

100

SEARCH ENA

0001

KEY

0: Press the STILL button or turn the search dial to engage search dial operation.

 

 

 

 

 

 

1: Press the STILL button to engage search dial operation.

 

 

 

 

 

 

 

 

 

 

 

0000

×8

Sets the maximum shuttle speed operation.

 

 

 

 

0001

×16

0: 8× normal speed

 

 

101

SHTL MAX

0002

×32

1: 16× normal speed

 

 

0003

×60

2: 32× normal speed

 

Setup

 

 

 

 

 

0004

×100

3: 60× normal speed

 

 

 

 

 

 

 

 

 

4: 100× normal speed

 

 

 

 

 

 

 

 

 

 

 

0000

×32

Sets the maximum speed of FF and REW operation.

 

 

 

 

0001

×60

0: 32× normal speed

 

 

 

 

0002

×100

1: 60× normal speed

 

 

 

 

0003

SEEK

2: 100× normal speed

 

 

102

FF.REW MAX

 

 

3: Seek operation to start of clip

 

 

 

 

 

 

NOTE:

 

 

 

 

 

 

• When SEEK is selected, FF and REW operations for FF and REW commands

 

 

 

 

 

 

transferred via 9P and 1394 are performed at 100× normal speed.

 

 

 

 

 

 

• The seek operation is available in playback mode.

 

 

 

 

 

 

 

 

 

 

 

0000

CLIP

Specifies where a NEXT (SHIFT+FF) and PREV (SHIFT+REW) seek operation moves to.

 

 

 

 

0001

CLIP&T

0: The start of the clip

 

 

103

SEEK SEL

 

 

1: The start of the clip or video text memo

 

 

 

 

 

 

NOTE:

 

 

 

 

 

 

This setting is not available during FF and REW operation.

 

 

 

 

 

 

 

 

 

 

 

0000

OFF

Selects whether or not a warning should appear when REF.VIDEO is not connected.

 

 

104

REF ALARM

0001

ON

0: Displays no warning

 

 

 

 

 

 

1: Flashes the STOP lamp to warn

 

 

 

 

 

 

 

 

 

 

 

0000

0

Sets PLAY delay time in frame increments.

 

 

108

PLAY DELAY

 

 

 

 

 

0015

15

 

 

 

 

 

 

 

 

 

 

 

 

0000

EE

Specifies whether to invoke the EE mode or playback mode when STOP is pressed.

 

 

 

 

0001

PB

0: EE mode

 

 

122

STOP EE SEL

 

 

1: Playback mode

 

 

 

 

 

 

NOTE:

 

 

 

 

 

 

During IEEE1394 signal input, the EE mode is invoked regardless of this menu setting.

 

 

 

 

 

 

 

 

 

Setup: Item Settings 125