Display

Description

Deck operation

 

 

 

 

 

 

No

Character code

 

 

 

 

 

 

 

 

 

 

50

BATTERY EMPTY

Displayed when a drop in the backup battery voltage for the internal clock is detected at

Operation

 

 

power on. Replace the internal battery. *4

continues

 

 

 

 

 

 

 

DIR NG

Directory structure does not comply with the P2 card standard.(* indicates the slot

Operation

 

 

70

number where the error occurred.) Make a quick backup of card data and format the

continues

 

 

CARD<******>

 

 

 

card.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RUNDOWN

The P2 card has been rewritten the maximum number of times.(* indicates the slot

Operation

 

 

71

number where the error occurred.) You are recommended to replace the card with a new

continues

 

 

CARD<******>

 

 

 

card.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

90

NOT 1× 100M SIG

Displayed when a signal input from the 1394 interface is not a DVCPRO HD (100 Mbps)

Recording is

 

 

1× normal speed transfer signal.

disabled

 

 

 

 

 

 

 

 

 

 

 

 

91

COPY PROTECTED

Displayed when DV format recording is available and the copy guard signal input via the

Recording is

 

 

1394 interface is in the copy inhibit mode.

disabled

 

 

 

 

 

 

 

 

 

 

 

 

92

1394 INITIAL ERROR

Displayed when the 1394 interface connection is irregular.

*3

 

 

 

 

 

 

 

 

 

 

Appears during playback when the time code has been recorded in drop frame mode.

Operation

 

 

 

 

The video output is distorted and audio output is muted at the drop point of the time code.

continues

 

 

 

 

Check the playback clip. Playing back a 24p frame-rate clip requires that the time code

 

 

 

 

 

 

 

 

93

INVALID TC MODE

be recorded in non-drop frame mode. Appears when the time code in an HD SDI input is

 

 

 

 

 

 

in the drop frame mode during EE or recording. Normal recording will not be possible

 

 

 

 

 

 

 

For

 

 

under these conditions. Check signal input to the unit. Set the input time code to non-drop

 

 

 

 

frame mode. (Appears when 23.98, 24, 59-23, 60-24 or 60-25 is set in setup menu No. 25

 

 

Long

 

 

SYSTEM FREQ.)

 

 

 

 

 

 

 

and

 

 

Displayed while synchronizing recorded video frames to the time code of a signal input

Operation

 

 

 

 

 

95

INVALID EMBEDDED

to the HD SDI connector when that time code is not advancing at 1× normal speed. (When

continues

 

Trouble

TC

“SLTC” is selected in setup menu No. 032 REC REF or 29.97, 59-23, 60-24, 25 or 60-25

 

 

 

 

 

 

 

 

 

 

 

is selected in setup menu No. 25 SYSTEM FREQ.)

 

 

 

 

 

 

 

 

Free-

 

 

Appears during playback when frame rate data in user bit cannot be detected or when

Operation

 

 

 

the playback time code is not continuous. The video output is distorted and audio output

continues

 

 

 

 

 

 

 

is muted in sections where the time code is not continuous. Check the playback clip.

 

 

Operation

 

INVALID TC

will not be possible under these conditions. Check signal input to the unit. Input signals

 

 

96

SEQUENCE

data in an HD SDI input or when the input time code is not continuous. Normal recording

 

 

 

 

 

 

 

 

 

with a matching time code and pull-down sequence (Appears when 23.98, 24, 59-23, 60-

 

 

 

 

 

24 or 60-25 is set in setup menu No. 25 SYSTEM FREQ.)

 

 

 

 

 

 

 

 

 

 

 

Appears when active frame data cannot be detected in the user bits in the HD SDI input

Recording is

 

 

 

 

during EE or recording. Normal recording will not be possible under these conditions.

disabled *5

 

 

97

NO ACTIVE FRAME

Check signal input to the unit. The input signal must contain the active frame data from a

Operation

 

 

 

 

variable frame-rate camera. (Appears when 29.97, 59-23, 60-24 or 60-25 is set in menu

continues during

 

 

 

 

No. 25 SYSTEM FREQ and menu No. 040 VFR REC is set to ON.)

recording

 

 

 

 

 

 

 

 

 

 

Appears when active frame data detected from the user bit in the HD SDI input during EE

Operation

 

 

98

INVALID FRAME

and recording exceeds 50p. Normal recording is not possible under these conditions.

continues

 

 

RATE

When SYSTEM FREQ is set to 60-25, set the frame rate on a variable frame-rate camera

 

 

 

 

 

 

 

 

 

to 50p or less. Appears when SYSTEM FREQ is set to 60-25 and VFR REC is set to ON.

 

 

 

 

 

 

 

 

 

NOTE:

*3 This warning appears at any time. This error disables input to the digital video interface.

*4 “E-50” appears when the backup battery is depleted. Consult your supplier for information on a store that can provide you with a new battery (CR2032 or the equivalent). Be sure to use setup menu No. 069 (CLOCK SET) to set the clock after battery replacement.

*5 An attempt to start recording causes the button to temporarily light. It goes out a few seconds later and no recording is made.

For Long and Trouble-Free Operation: Error Messages 155