For details, refer to “Simplified Voice-Over” (page 95), and “Copying Event Audio to EXTRA track” (page 87).

15.REC button

Press this button and the PLAY button simultaneously to start recording. Press this button during playback mode to check EE mode video and audio on the monitor (EE mode is not available during IEEE1394 input). Press the STOP button to return to the original video and audio.

To start AUTO CAPTURE when the unit is controlled from an external device, hold down the SHIFT button and press the REC button.

Refer to “External Remote Control” (page 113).

16.REW/PREV button

Press to rewind. Select the speed in setup menu No. 102 (FF. REW MAX).

During playback, hold down the SHIFT button and press the REW button to move to the beginning of the current or previous clip.

During GUI display (thumbnail display and event list display), hold down the SHIFT button and press the REW button to move to the first thumbnail or event.

20.TCG switch

INT REGEN:

The internal time code generator

 

synchronizes with the time code

 

read by the time code reader from

 

the P2 card. Select whether to make

 

TC or UB the REGEN in setup menu

 

No. 505 (TCG REGEN).

 

 

INT PRESET:

Uses the internal time code

 

generator of this unit. Settings can

 

be preset on the operation panel

 

and the remote control panel.

 

Refer to “Time Code, User Bit and

 

CTL” (page 142).

 

 

EXT:

Uses the external time code input

 

from the TIME CODE IN connector

 

or video signal VITC, SLTC, SVITC

 

and IEEE1394 digital input

 

connectors. Select in setup menu

 

No. 507 (EXT TC SEL).

21.COUNTER button

Press to switch the counter display of the LCD panel. Each press of this button changes the counter display as follows: [CTL (relative position from the beginning)]

[TC (read time code)] [UB (user bit of the read time code)].

Introduction

17.STILL/PAUSE button

Press this button to engage the search mode and display a still picture. In the search mode, you can use the search dial for JOG and SHTL (shuttle) operations.

18.STOP button

Press this button to stop. When the setting in setup menu No. 122 (STOP EE SEL) is PB, you can monitor still pictures and when set to EE, you can monitor input video.

22.RESET button

Press this button when the LCD panel counter is in the CTL mode to reset the counter display to [0:00:00:00]. Hold down the TC PRESET button and press this button when the LCD panel counter is in the TC mode (read time code) or UB mode (user bit of the read time code) to reset the time code generator.

When using the on-screen keyboard, use this button to delete all text, IN points in play lists, etc.

19.PLAY/REVIEW button
23.TC PRESET button

Set the TC (read time code) or UB (user bit of read time

Press to start playback.

code) value.

Press this button and the REC button simultaneously to

To make a setting, first press this button to change the

start recording.

flashing digits. However, this function is not available

When the play list is displayed, hold down the SHIFT

while in thumbnail mode, play list mode, and USB host

button and press this button to review (playback

mode.

starting 3 seconds before the IN point continuing to 1 second beyond the OUT point) an event at the pointer position. The overwrite edit mode permits preview of unfinalized events.

To play back the clip at the cursor location in the thumbnail screen, hold down the SHIFT button and press this button.

Introduction: Control Reference Guide 19