Item

Setting

 

 

 

 

 

Settings and brief function description

FR

SUPER

FR

SUPER

No.

DISP.

No.

DISP.

 

 

 

 

 

 

 

 

0000

OFF

Select whether recording and stopping should be performed automatically according to

 

 

0001

TYPE1

the Recording Marks in the HD SDI input signals from Panasonic camera-recorders.

 

 

0002

TYPE2

0: No automatic recording/stopping

 

 

 

 

1: Recording and stopping is performed automatically according to the Recording Marks

 

 

 

 

in the LTC information attached to HD SDI signals.

 

 

 

 

2: Recording and stopping is performed automatically according to the Recording Marks

 

 

 

 

in the SVITC information attached to HD SDI signals.

155

AUTO REC

 

 

NOTE:

 

 

• Set the CONTROL switch to REMOTE. Refer to “Panasonic camera-recorders,

 

 

 

 

 

 

 

 

recording formats and Recording Mark” on the next page before selecting TYPE1 or

 

 

 

 

TYPE2.

 

 

 

 

• Select TYPE1 or TYPE2. To start automatic recording, simultaneously press the REC

 

 

 

 

button and the STILL button to place this unit in the REC PAUSE mode. This function

 

 

 

 

will not work in any mode other than REC PAUSE. The unit returns to REC PAUSE

 

 

 

 

mode when automatic stop is activated.

 

 

 

 

• In normal recording mode, this setting is not available and auto stop is not activated.

 

 

 

 

 

 

 

0000

OFF

Determines whether or not to engage repeat play during playback.

 

 

0001

ON

0: Does not engage repeat play. Stops playback at the end of the last clip.

 

 

 

 

1: Engages repeat play. Continues playback from the beginning when reaching the end

 

 

 

 

of the last clip.

 

 

 

 

NOTE:

160

REPEAT PLAY

 

 

• Repeat play is not available when the PLAYLIST button is on and during TEXT MEMO

 

 

 

 

playback.

 

 

 

 

• If the P2 card is removed during repeat play, playback is suspended when playback

 

 

 

 

reaches the clip that is no longer exists.

 

 

 

 

• Even if you insert a P2 card during repeat play, additional clips are not played back

 

 

 

 

until you once stop repeat play and resume it.

 

 

 

 

 

 

 

0000

NiCd12

Sets the battery type.

 

 

0001

NiCd13

0: Settings for 1 pc. 12 V battery (NEAR: 11.2 V, END: 10.6 V)

 

 

0002

NiCd14

1: Settings for 1 pc. 13 V battery (NEAR: 12.0 V, END: 10.6 V)

180

BATTERY SEL

0003

S-LION

2: Settings for 1 pc. 14 V battery (NEAR: 13.6 V, END: 10.6 V)

0004

I-LION

3: Settings for 1 pc. lithium-ion battery (BP-L90A) (NEAR: 11.0 V, END: 10.6 V)

 

 

 

 

0005

TYPE-A

4: Settings for 1 pc. lithium-ion battery (ENDURA80) (NEAR: 13.4 V, END: 10.6 V)

 

 

0006

TYPE-B

5: Battery specified by menu No. 181 TYPE-A NEAR item and No. 182 TYPE-A END item

 

 

 

 

6: Battery specified by menu No. 183 TYPE-B NEAR item and No. 184 TYPE-B END item

 

 

 

 

 

 

 

0000

10.6

Specifies the voltage (in 0.1 V steps) when the counter display will flash to warn that the

 

 

voltage of a TYPE-A battery selected in menu No. 180 BATTERY SEL item has dropped.

181

TYPE-A NEAR

0023

12.9

NOTE:

• When a setting is made in the vicinity of 15.0 V, the counter display may flash also

 

 

 

 

0044

15.0

when AC power is used.

 

 

 

 

• A setting that is smaller than END cannot be made.

 

 

 

 

 

 

 

0000

10.6

Specifies the voltage (in 0.1 V steps) when this unit will automatically power off because

 

 

the voltage of a TYPE-A battery selected in menu No. 180 BATTERY SEL item has

182

TYPE-A END

0018

12.4

dropped.

 

 

NOTE:

 

 

0034

14.0

A setting that is larger than NEAR cannot be made.

 

 

 

 

 

 

 

0000

10.6

Specifies the voltage (in 0.1 V steps) when the counter display will flash to warn that the

 

 

voltage of a TYPE-B battery selected in menu No. 180 BATTERY SEL item has dropped.

183

TYPE-B NEAR

0023

12.9

NOTE:

• When a setting is made in the vicinity of 15.0 V, the counter display may flash also

 

 

 

 

0044

15.0

when AC power is used.

 

 

 

 

• A setting that is smaller than END cannot be made.

 

 

 

 

 

126 Setup: Item Settings