WARNING information display

A warning message is displayed whenever a warning occurs.

When no warnings have been detected, “NO WARNING” is displayed.

When multiple warnings occur, turn the search dial to check the descriptions of each warning.

If “T&S&M” is selected in setup menu No. 006 (DISPLAY SEL), a message appears in the mode display whenever a warning or error occurs.

Monitor display

Description

Deck operation

Counter display

 

 

 

 

 

 

 

 

 

Displayed when audio voice-over cannot be recorded on a P2 card.

 

 

 

 

CANNOT A.DUB

[Meaning]

STOP

CANTADUB

 

 

• An attempt was made to record on a card that could not be used.

 

 

 

 

 

 

 

 

• An attempt was made to record when no card was inserted

 

 

 

 

 

 

 

 

 

 

PLEASE SAVE

Displayed when A. DUB is started without saving the play list.

STOP

CANTADUB

 

 

PLAYLIST

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WRITE

Appears when a voice-over recording is attempted on a write-protected P2 card.

STOP

CANTADUB

 

 

PROTECTED

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LACK OF REC

Appears when a voice-over recording is attempted on a P2 card without enough

STOP

CANTADUB

 

 

CAP.

capacity.

 

For

 

 

 

 

 

 

 

 

 

 

 

 

 

MAX A.DUB

Appears when a voice-over recording is attempted on a P2 card where the

STOP

CANTADUB

 

Long

EVENTS

number of voice-over audio recordings has already reached the upper limit.

 

 

 

 

 

 

 

 

 

 

 

 

and

 

Displayed when data cannot be recorded on a P2 card.

 

 

 

 

[Meaning]

 

 

 

 

 

 

 

Trouble

 

• An attempt was made to record to a write protected disk.

 

 

 

 

 

 

 

 

 

• An attempt was made to record data on a card with no more free memory space

 

 

 

 

CANNOT REC

on it.

STOP

CANT REC

 

Free-

 

• An attempt was made to record on a card with no free space available.

 

 

 

 

 

 

 

 

 

• Card status changed during recording.

 

 

 

Operation

 

• Recording was attempted when the unit was BUSY.

 

 

 

 

 

 

 

 

 

• VFR recording started but no active frame data was input.

 

 

 

 

 

 

 

 

 

 

 

Appears in LOOP REC mode when P2 card recording is not available.

 

 

 

 

 

[Meaning]

 

 

 

 

CANNOT LOOP

• An attempt was made to record to a write protected disk.

 

 

 

 

• An attempt was made to record on a card with no free space available.

STOP

CANTLREC

 

 

REC

 

 

• An attempt was made to record on a card that could not be used.

 

 

 

 

 

 

 

 

 

 

• Card status changed during recording.

 

 

 

 

 

• Recording was attempted when the unit was BUSY.

 

 

 

 

 

 

 

 

 

 

 

Displayed when playback was interrupted due to a clip error or other factor.

 

 

 

 

 

[Meaning]

 

 

 

 

CANNOT PLAY

• An attempt was made to play a clip when no clips were present.

STOP

CANTPLAY

 

 

• An attempt was made to play back a card that cannot be used

 

 

 

 

 

 

 

 

• The card could not be played back or playback stopped for some other reason

 

 

 

 

 

• Playback was attempted when the unit was BUSY.

 

 

 

 

 

 

 

 

 

 

CANNOT ENTRY

Displayed when an attempt was made to register an IN, OUT or SPLIT point in a

Operation

CANT ENT

 

 

location where such points cannot be registered.

continues

 

 

 

 

 

 

 

 

 

 

 

 

CHECK A.SPLIT

Displayed when an audio split setting prevents the registration of an IN, OUT and

Operation

CANT ENT

 

 

POINT

SPLIT points.

continues

 

 

 

 

 

 

 

 

 

 

 

OVER DUR TIME

Displayed when an attempt was made to register a duration exceeding 24 hours.

Operation

CANT ENT

 

 

 

continues

 

 

 

 

 

 

 

 

 

 

 

 

 

CHECK

Recorder range not large enough for registered player IN and OUT points.

Operation

 

 

 

RECORDER

 

CANT ENT

 

 

 

continues

 

 

RANGE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CHECK PLAYER

Player range not large enough for registered recorder IN and OUT points.

Operation

CANT ENT

 

 

RANGE

 

continues

 

 

 

 

 

 

 

 

 

 

 

 

MAX EVENTS

The number of events that can be registered on the play list has been reached.

Operation

CANT ENT

 

 

 

continues

 

 

 

 

 

 

 

 

 

 

 

 

 

For Long and Trouble-Free Operation: Error Messages 153