Monitor display

Description

Deck operation

Counter display

 

 

 

 

INVALID

Appears when there are already 100 text memos and no more memos can be

Operation

INVALID

added.

continues

 

 

 

 

 

 

 

Displayed while clip information is being read or when clip configuration has

 

 

 

changed. No operations can be performed while this display is on the screen.

 

 

 

[Meaning]

Operation

 

BUSY

• A card has been inserted or removed.

BUSY

continues

 

• Updating is in progress

 

 

 

 

 

• Recording post processing is in progress

 

 

 

• Other causes

 

 

 

 

 

 

 

Displayed for the first two seconds when the REC button is pressed to enter the

Operation

 

INT SG

EE mode and the INPUT SELECT VIDEO button or the INPUT SELECT AUDIO

INT SG

continues

 

button is set to SG.

 

 

 

 

 

 

 

 

 

Displayed for the first two seconds when the REC button is pressed to enter the

Operation

 

NO INPUT

EE mode and the INPUT SELECT button is set to a connector with no output

NO INPUT

continues

 

except for analog audio signals.

 

 

 

 

 

 

 

 

TEXT MEMO

Displayed for two seconds when a text memo is added.

Operation

TEXT MEMO

 

continues

 

 

 

 

 

 

 

MARK ON/OFF

Displayed for two seconds when a shot mark is added or deleted.

Operation

MARK ON /

 

continues

MARK OFF

 

 

 

 

 

 

WARNING information

If “E- * * ” Iights in the monitor display, hold down the SHIFT button and press the MENU button to open the DIAG-MENU and

read the warning information.

 

Display

Description

Deck operation

 

 

No

Character code

 

 

 

 

 

 

04

UNKNOWN SIG

Displayed when a signal input from the 1394 interface is not a DVCPRO or DV format

Recording is

signal.

disabled

 

 

 

 

 

 

10

FAN STOP

Displayed when the fan motor stops.

Operation

 

continues

 

 

 

 

 

 

 

11

NOT 1× 25M SIG

Displayed when a signal input from the 1394 interface is not a DVCPRO (25 Mbps) 1×

Recording is

normal speed transfer signal.

disabled

 

 

 

 

 

 

12

NOT 1× 50M SIG

Displayed when a signal input from the 1394 interface is not a DVCPRO50 (50 Mbps) 1×

Recording is

normal speed transfer signal.

disabled

 

 

 

 

 

 

14

NO MATCH SIG

Displayed when signal input via the 1394 interface differs from the system format set on

Recording is

this unit.

disabled

 

 

 

 

 

 

15

NOT 1× DV SIG

Displayed when a signal input from the 1394 interface is not a DV (25 Mbps) 1× normal

Recording is

speed transfer signal.

disabled

 

 

 

 

 

 

16

INVALID VIDEO SIG

Displayed when the compressed video data of a signal input from the 1394 interface is

Recording is

irregular.

disabled

 

 

 

 

 

 

17

INVALID AUDIO SIG

Displayed when the audio data of a signal input from the 1394 interface is irregular.

Operation

 

continues *1

 

 

 

18

INVALID TC SIG

Displayed when the time code data of a signal input from the 1394 interface is irregular.

Operation

 

continues *2

 

 

 

21

REC WARNING

Displayed when a video or audio error occurs during recording.

STOP

To continue operation, turn the power off and then back on again.

 

 

 

 

 

 

 

 

 

 

Displayed when data was corrupted due to a P2 card error during recording.

STOP

 

CARD

This error is displayed after recording ends and until the start of the next operation. This

 

26

error is not displayed during playback. (* indicates the slot number where the error

 

ERROR<******>

 

 

occurred.)

 

 

 

 

 

 

Replace the P2 card in the slot where the error occurred.

 

 

 

 

 

NOTE:

*1 This warning appears only during recording. Then the audio is recorded mute.

*2 This warning appears only during recording. The internally generated time code is recorded.

154 For Long and Trouble-Free Operation: Error Messages