TIME CODE

This menu sets the time code.

 

 

 

 

 

 

* An underlined setting indicates an initial value.

 

 

 

 

 

 

 

Item

 

Setting

 

 

 

 

 

 

 

 

Settings and brief function description

FR

SUPER

FR

 

SUPER

 

No.

DISP.

No.

 

DISP.

 

 

 

 

 

 

 

 

 

 

 

0000

 

BLANK

59.94Hz

50Hz 29.97Hz 25Hz only

 

 

0001

THRU

 

 

Specifies whether or not a VITC signal will be output at the positions selected in menu No.

 

 

 

 

 

 

 

 

 

 

501 VITC POS-1 and No. 502 VITC POS-2 during playback.

500

VITC BLANK

 

 

 

0: VITC signals are not output.

 

 

 

1: VITC signals are output.

 

 

 

 

 

NOTE:

This setting is available only during analog composite output and SD SDI output.

In EE mode, the input signal is output with the VITC signal.

 

 

When set to 59.94 Hz,

59.94Hz

50Hz

29.97Hz

25Hz

only

 

 

29.97 Hz

 

 

Specifies the position where the VITC signal will be inserted.

 

 

 

 

 

 

 

0000

 

10L

NOTE:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• You cannot select the same line as in menu No. 502 VITC POS-2.

 

 

0006

 

16L

 

 

 

• This setting is available only during analog composite output and SD SDI output.

 

 

 

 

 

 

 

 

 

 

 

501

VITC POS-1

0010

 

20L

 

 

 

 

 

 

 

 

 

 

 

 

 

When set to 50 Hz,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

25 Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0000

 

7L

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0004

 

11L

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0015

 

22L

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

When set to 59.94 Hz,

59.94Hz

50Hz

29.97Hz

25Hz

only

 

 

29.97 Hz

 

 

Specifies the position where the VITC signal will be inserted.

 

 

 

 

 

 

 

0000

 

10L

NOTE:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• You cannot select the same line as in menu No. 501 VITC POS-1.

 

 

0008

 

18L

 

 

 

• This setting is available only during analog composite output and SD SDI output.

 

 

 

 

 

 

 

 

 

 

 

502

VITC POS-2

0010

 

20L

 

 

 

 

 

 

 

 

 

 

 

 

 

When set to 50 Hz,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

25 Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0000

 

7L

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0006

 

13L

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0015

 

22L

 

 

 

 

 

 

 

 

 

 

 

 

0000

 

REC Specifies an operating mode that advances the internal time code generator.

 

 

0001

 

FREE

0: The internal time code generator is advanced only during recording.

 

 

 

 

 

1: When the power is on, the internal time code generator is advanced regardless of

504

RUN MODE

 

 

 

operating mode.

 

 

 

 

 

 

 

 

NOTE:

 

 

 

 

 

 

 

 

 

• When menu No. 040 VFR REC is set to ON, the time code advances only during

 

 

 

 

 

recording even when FREE is selected.

 

 

 

 

 

 

 

 

 

0000

 

TC&UB

Specifies the signal to regenerate when the time code generator (TCG) is in the REGEN

 

 

0001

 

TC

mode.

 

 

 

 

505

TCG REGEN

0002

 

UB

0: Regenerates both the time code and the user bit

 

 

 

 

 

1: Regenerates only the time code

 

 

 

 

 

 

 

2: Regenerates only the user bit

 

 

 

 

 

 

 

 

 

 

 

 

128 Setup: Item Settings