5. Setting menu table

 

Menu

Sub menu

 

Parameter 1

 

Parameter 2

 

Parameter 3

 

Parameter 4

 

Use [F1] to select.

 

Use [F2] to select.

 

Use [F3] to select.

 

Use [F4] to select.

 

Use [F5] to select.

 

 

 

 

 

 

XPT

 

XPT Assign 1/6

Parameter

XPT1Signal

 

XPT2Signal

 

XPT3Signal

 

XPT4Signal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Setting range

SDI IN1 to 8, DVI IN, IN-A1, IN-A2, IN-B1, IN-B2, Black, CBGD1,

 

 

 

 

CBGD2, CBAR, Still1V, Still1K, Still2V, Still2K, Clip1V, Clip1K,

 

 

 

 

Clip2V, Clip2K, MEM-PVW, CLN, KeyOut, None

 

 

 

 

 

Default value

Black

 

SDI IN1

 

SDI IN2

 

SDI IN3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

XPT Assign 2/6

Parameter

XPT5Signal

 

XPT6Signal

 

XPT7Signal

 

XPT8Signal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Setting range

The setting range is the same as for the XPT Assign 1/6 sub menu.

 

 

 

 

 

 

 

Default value

SDI IN4

 

SDI IN5

 

SDI IN6

 

SDI IN7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

XPT Assign 3/6

Parameter

XPT9Signal

 

XPT10Signal

 

XPT11Signal

 

XPT12Signal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Setting range

The setting range is the same as for the XPT Assign 1/6 sub menu.

 

 

 

 

 

 

 

Default value

SDI IN8

 

DVI IN

 

IN-A1

 

None

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

XPT Assign 4/6

Parameter

XPT13Signal

 

XPT14Signal

 

XPT15Signal

 

XPT16Signal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Setting range

The setting range is the same as for the XPT Assign 1/6 sub menu.

 

 

 

 

 

 

 

Default value

IN-A2

 

IN-B1

 

IN-B2

 

CBAR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

XPT Assign 5/6

Parameter

XPT17Signal

 

XPT18Signal

 

XPT19Signal

 

XPT20Signal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Setting range

The setting range is the same as for the XPT Assign 1/6 sub menu.

 

 

 

 

 

 

 

Default value

CBGD1

 

Still1V

 

Still2V

 

None

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

XPT Assign 6/6

Parameter

XPT21Signal

 

XPT22Signal

 

XPT23Signal

 

XPT24Signal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Setting range

The setting range is the same as for the XPT Assign 1/6 sub menu.

 

 

 

 

 

 

 

Default value

KeyOut

 

CLN

 

None

 

None

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

XPT Setting

Parameter

Shift

 

Shift-Lock

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Setting range

Off, Right, Left

 

On, Off

 

 

 

 

 

 

 

Default value

Right

 

Off

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

XPT Switch

Parameter

Timing

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Setting range

Any, Field1,

 

 

 

 

 

 

 

 

 

 

Field2

 

 

 

 

 

 

 

 

 

Default value

Any

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

128