2. Input/output signal settings
The frame synchronizer can be set to On or Off for each input. The DVI input frame synchronizer is permanently On.
It cannot be set from On to Off or vice versa.
1On the Input sub menu, use [F2] to select the input to be set using the Select item.
Refer to
2Use [F1] to display the FS sub menu.
3Use [F2] to set On or Off for the frame synchronizer using the FS item.
If the output signal phase is set to 0H, Off cannot be selected as the FS item setting.
AVDL function is active while the frame synchronizer function is set to Off.
The AVDL function automatically adjusts the input image signal phase to the horizontal synchronization reference signal phase.
For details, refer to
76