2. Input/output signal settings

2-1-3. Setting the delay amount

The input signals can be delayed.

ppThe delay can be applied only to the SDI IN7 and SDI IN8 input signals.

1On the Input sub menu, use [F2] to select the input to be set using the Select item.

Refer to “2-1. Input signal settings”.

2Use [F1] to display the FS sub menu.

3Use [F4] to set the delay amount using the Delay item.

2-1-4. Freezing the input signals

The input signals can be frozen and used.

While signals are frozen, the tally signals of the corresponding input will not be output.

Setting freeze

1On the Input sub menu, use [F2] to select the input to be set using the Select item.

Refer to “2-1. Input signal settings”.

2Use [F1] to display the Freeze sub menu.

3Use [F2] to select the freeze method using the Select item.

Frame

The images are frozen frame by frame.

Field

The images are frozen field by field.

 

This is used to freeze moving images.

 

With interlace signals, however, diagonal

 

lines and moving parts appear jagged.

Frame or Field can also be selected while an image is frozen.

4Press the [F3] to freeze the input image or cancel the freeze.

If the [F3] is pressed while the display is “Off”, the video signal is frozen, and the display is set to “On”.

If the [F3] is pressed while the display is “On”, the video signal freezing is canceled, and the display is set to “Off”.

The “F” mark appears in front of the name of the material when the signals set for output of multi view displays are frozen.

ppWhen the unit is used with the frame synchronizer function OFF, the output images may be disturbed when freezing is executed, but the frozen images will not be adversely affected.

ppIf, when the switcher is used with the frame synchronizer function at OFF, “On” is set as the freeze setting, the frame synchronizer function will be automatically switched to ON.

2-1-5. Setting the material names

Material names can be given to the input signals.

These names can be selected from the default settings or user settings.

1On the Input sub menu, use [F2] to select the input to be set using the Select item.

Refer to “2-1. Input signal settings”.

2Use [F1] to display the Name sub menu.

3Use [F2] to select the type of material names using the Type item.

Default

Select the material names from the following:

(default

SDI IN1 to SDI IN8, DVI IN, IN-A1, IN-A2,

settings)

IN-B1 and IN-B2.

User

The material names are set using up to 7

(user

characters.

settings)

 

78