5. Setting menu table

Menu

Sub menu

 

Parameter 1

Parameter 2

Parameter 3

Parameter 4

Use [F1] to select.

 

Use [F2] to select.

Use [F3] to select.

Use [F4] to select.

Use [F5] to select.

 

 

Input

Input

Parameter

Select ()

 

 

 

 

 

Setting range

SDI IN1 to 8,

 

 

 

 

 

 

DVI IN,

 

 

 

 

 

 

IN-A1, IN-A2,

 

 

 

 

 

 

IN-B1, IN-B2

 

 

 

 

 

Default value

SDI IN1

 

 

 

 

 

 

 

 

 

 

 

Input (SDI)

FS

Parameter

FS

Mode

Delay

 

/ X ()

 

 

 

 

 

 

 

 

Setting range

On, Off

Normal,

0 to 8f

 

SDI IN1 to SDI IN8,

 

 

 

 

Dot by Dot,

(Only SDI IN7

 

 

 

 

 

Up Convert,

and SDI IN8 are

 

IN A1, IN A2, IN B1

 

 

 

 

involved here.)

 

 

 

 

 

Auto

 

or IN B2 is displayed

 

 

 

 

 

 

 

 

 

 

 

in the X part.

 

 

 

 

(Only SDI IN5

 

 

 

 

 

 

to SDI IN8 are

 

 

The material name

 

 

 

 

 

 

 

 

 

 

covered by the

 

 

(up to 10 characters)

 

 

 

 

 

 

 

 

 

 

“Up Convert” and

 

 

is displayed in the

 

 

 

 

 

 

 

 

 

 

“Auto” modes.)

 

 

 part.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Default value

On

SDI IN1 to

0f

 

 

 

 

 

 

SDI IN4:

 

 

 

 

 

 

 

Normal

 

 

 

 

 

 

 

SDI IN5 to

 

 

 

 

 

 

 

SDI IN8:

 

 

 

 

 

 

 

Auto

 

 

 

 

 

 

 

 

 

 

 

Freeze

Parameter

Select

Freeze

 

 

 

 

 

 

 

 

 

 

 

 

Setting range

Frame, Field

On, Off

 

 

 

 

Default value

Frame

Off

 

 

 

 

 

 

 

 

 

 

 

Name

Parameter

Type

Name

 

 

 

 

 

 

 

 

 

 

 

 

Setting range

Default, User

 

 

 

 

 

Default value

Default

 

 

 

 

 

 

 

 

 

 

 

 

Up Converter1

Parameter

Scale

Move Detect

Sharp

Size

 

 

 

 

 

 

 

 

 

(SDI IN5 to

Setting range

Squeeze,

1 to 5

1 to 5

100 to 110

 

SDI IN8, IN A1,

 

Edge Crop,

 

 

 

 

IN A2, IN B1, and

 

Letter Box

 

 

 

 

IN B2 only)

 

 

 

 

 

Default value

Squeeze

3

3

100

 

 

 

 

 

 

 

 

 

 

 

Up Converter2

Parameter

Edge Crop Pos

 

Limiter

 

 

 

 

 

 

 

 

 

 

(SDI IN5 to

Setting range

Center, Right,

 

Off, 108, 104,

 

 

SDI IN8, IN A1,

 

Left

 

100

 

 

IN A2, IN B1, and

 

 

 

 

(Only IN A1,

 

 

IN B2 only)

 

 

 

 

IN A2, IN B1 and

 

 

 

 

 

 

 

IN B2 are involved

 

 

 

 

 

 

 

here.)

 

 

 

Default value

Center

 

Off

 

 

 

 

 

 

 

 

 

 

Video Process1

Parameter

Video Process

Y-Gain

Pedestal

 

 

 

 

 

 

 

 

 

 

 

Setting range

On, Off

0.0 to 200.0

20.0 to 20.0

 

 

 

Default value

Off

100.0

0.0

 

 

 

 

 

 

 

 

 

 

Video Process2

Parameter

 

 

C-Gain

Hue

Copy From ()

 

 

Setting range

 

 

0.0 to 200.0

0.0 to 359.9

SDI IN1 to

 

 

 

 

 

 

 

SDI IN8

 

 

Default value

 

 

100.0

0.0

Default values

 

 

 

 

 

 

 

vary depending

 

 

 

 

 

 

 

on the selections

 

 

 

 

 

 

 

of the Select

 

 

 

 

 

 

 

items in the Input

 

 

 

 

 

 

 

submenu.

 

 

 

 

 

 

 

 

 

: When the Select item is SDI IN1: SDI IN2

 

 

 

 

 

When the Select item is other than SDI IN1: SDI IN1

 

 

 

 

 

 

 

 

130