1. Basic operations

1-10-7. Registering the material selection items

Set whether or not to register the “Material selection” items of the buses.

Refer to “1-10-1. Memory registration and recall items”.

1 Press the ebutton to light its indicator, and display the Shot Memory menu (or Event Memory menu).

2Use [F1] to display the XPT Disable sub menu.

3Use [F2] to set the BKGD item, [F3] to set the Key item, [F4] to set the PinP1 item, and [F5] to set the PinP2 item.

Off

The “Material selection” items are not

 

registered in the memories.

On

The “Material selection” items are registered

 

in the memories.

ppWhen the [XPT DSBL] button is pressed, its indicator lights in red.

The materials of the “Material selection” items registered in the buses are canceled.

1-10-8. Setting effect dissolve(shot memory)

Switching from the current image to the image or operation stored in the shot memory can be performed smoothly.

1Press the ebutton to light its indicator, and display the Shot Memory menu.

2Use [F1] to display the Path sub menu.

3Use [F2] to set the effect used for switching the images using the Effect item.

Dissolve

The images are switched using the dissolve

 

effect.

Cut

The images are switched using the cut effect.

ppThe dissolve effect duration is set in the Effect Dissolve sub menu which is selected in the Time menu.

4Use [F3] to set the PinP bus transition using the PinP Bus item.

Dissolve

The PinP bus images are switched using the

 

dissolve effect.

Cut

The PinP bus images are switched using the

 

cut effect.

5Use [F4] to select the effect used for switching the colors using the Hue Path item.

The following colors are targeted by Hue.

ppColors of the color background ppColors of the borders ppColors of the edges ppColors of the fill matte

Short

The colors are changed toward less hue on

 

the vectorscope.

Long

The colors are changed toward more hue on

 

the vectorscope.

CW

The Hue is changed clockwise on the

 

vectorscope.

CCW

The Hue is changed counterclockwise on the

 

vectorscope.

ppPressed number keys blink in green while the operation switching is underway.

ppWhen the operation switching has been completed, the pressed number key lights in amber.

ppWhen the Effect item is changed from “Dissolve” to “Cut” while operation is being switched, the dissolve effect is released, and the images are switched to the images of the selected shot memory in an instant.

ppWhen the PinP Bus item is changed from “Dissolve” to “Cut” while operation is being switched, the dissolve effect is released, and the PinP images are instantly switched to the PinP images of the selected shot memory.

ppDuring the operation switching, the operation of the fader lever is canceled.

ppDuring the operation switching, other stored operations cannot be recalled.

ppWhen initiating PinP1/2 transitions, the switching process is not stored in the memory.

52