1. Basic operations

1-13. Waveform monitor settings

 

VECTOR (vectorscope) settings

 

 

 

 

 

 

WFM (waveform monitor) settings

 

 

 

 

 

1 Press the [WFM/VECT] button among the display mode buttons to display the waveform monitor on the built-in display.

2 Press the sbutton to light its indicator, and display the Config menu.

3 Use [F1] to display the WFM sub menu.

4Use [F2] to select the method to be used to display the signal waveforms using the Style item.

Parade

The signal waveforms are arranged and

 

displayed.

Overlay

The signal waveforms are superimposed onto

 

each other and displayed.

5Use [F3] to select the signals whose waveforms are to be displayed using the Mode item.

YPbPr

Waveforms of the Y, PB and PR signals are

 

displayed.

RGB

Waveforms of the R, G and B signals are

 

displayed.

Y

Waveforms of the Y signal only are displayed.

1 Press the [WFM/VECT] button among the display mode

buttons to display the vectorscope on the built-in display. s

2 Press the

button to light its indicator, and display the

Config menu.

 

3Use [F1] to display the Vector sub menu.

4Use [F2] to select the color bar reference marker using the Bar Target item.

75%

The 75% color bar reference marker is

 

displayed.

100%

The 100% color bar reference marker is

 

displayed.

72