1. Basic operations

1-4-7. Linking PinP1 and PinP2

The PinP1 and PinP2 images perform a symmetrical operation for the axis whose coordinates and rotation angle have been set.

The image serving as the reference is the PinP image of the menu being operated.

Setting the priority

Set the relative positions of the images when key, PinP1 and PinP2 images are to be superimposed onto one another.

Refer to “1-3-10. Setting the priority”.

Linking PinP1 and PinP2

1Press the pbutton to light its indicator, and display the PinP1 menu (or PinP2 menu).

2Use [F1] to display the Sync sub menu.

3Use [F2] to select the position that will serve as the reference using the Symmetry item.

The image serving as the reference is the PinP image of the menu being operated.

When “X” has been selected as the Symmetry setting

The coordinates and rotation angle are made symmetrical to the X axis.

When “Y” has been selected as the Symmetry setting

The coordinates and rotation angle are made symmetrical to the Y axis.

When “Center” has been selected as the Symmetry setting

The coordinates and rotation angle are made symmetrical to the center.

Copying the settings

The PinP1 settings can be copied to PinP2 and, similarly, the PinP2 settings can be copied to PinP1.

1On the PinP1 menu (or PinP2 menu), use [F1] to display the Sync sub menu.

2Use [F2] to select “Off” using the Symmetry item.

3When [F5] is pressed, the PinP1 (or PinP2) settings are copied and set in PinP2 (or PinP1).

Note

The following settings are not copied. ppTrim sub menu items

32