Notes:
•During the alarm acknowledgement (ACK) status (refer to p. 31), event information is highlighted.
•When two or more alarm events have occurred, "∗" is displayed beside the event.
•When an alarm occurs and its display mode setting is OFF (refer to p. 30), "#" is displayed beside the event information.
•When auto tracking is scheduled for a camera event, "#" is displayed beside the camera number.
•q to r can be displayed or hidden either altogether or separately. Refer to p. 36 Lists of Functions and Operations for details.
■System Controller Display Information
The following are the details on terminal mode operations. For PS·Data operations, refer to p. 48 OPERATION (OTHER THAN THE TERMINAL MODE) or the operating instructions of system controllers.
●WV-CU950/650
q w e
r t y
qMonitor Number
Mon01 to 32: Monitor number
wCamera Number
Cam001 to 999: Camera number
eEvent
HDR01 to 16: Recorder number
Pre000 to 256 (Lighting for 3.0 seconds): Preset position
Note: Pre000 is the home position.
rBusy
Busy + monitor number (Blinking)
A selected monitor is controlled by a
Note: You cannot control the selected monitor, camera, and recorder.
Busy + camera/recorder number (Blinking)
A selected camera or recorder is controlled by a high-
Note: You cannot control the selected camera or recorder.
tStatus
Alarm (Blinking): Alarm is occurring.
Alarm (Lighting): Alarm is acknowledged. (Refer to p. 31.)
Memory + preset position number (Blinking for 3.0 sec- onds): Preset position is registered.
ySequence Number
Note: During sequence pause, "P" is displayed beside the sequence number.
Note: This sign disappears when the camera is con- trolled.
Invalid (Blinking for 3.0 seconds): You have entered a wrong value.
Not Avail (Blinking for 3.0 seconds):
•You cannot select a monitor because of lower priori- ty.
•You have tried to activate a group sequence or group preset on a monitor not assigned.
Prohibited (Blinking for 3.0 seconds): You have tried an operation restricted by the level setting.
Alarm Buzzer/Button Buzzer Setting
With the setting activated:
•Alarm buzzer can sound when alarms occur.
•Button buzzer can sound when a button is pressed or an error message (Invalid, Prohibited, Level1 Fixed, etc.) is displayed on the LCD.
Refer to the operating instructions of system controller for settings.