Notes:

When changing connections, perform the LCN settings of camera channels supplying video input signals to recorders. The LCN settings are performed in "System" – "Recorder" – "Logical Camera Number".

Camera input signals are looped through the unit. Monitor display information (camera title, etc.) are not recorded.

Video input signals are supplied from recorders to the CAMERA IN 31 and 32.

 

 

 

 

 

 

 

4

 

3

 

 

2

 

1

 

 

EXTENSION 3

IN

 

EXTENSION 2 IN

 

MODE

RS485 (CAMERA)

 

MODE

MODE

 

RS485 (CAMERA)

MODE

 

IN C-3

VIDEO OUT 4

 

 

VIDEO OUT 3

 

 

 

VIDEO OUT 2

 

 

VIDEO OUT 1

 

 

 

ALARM IN

IN X-2

32

31

30

29

28

27

26

25

24

23

 

22

21

20

19

18

17

16

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

 

 

 

 

 

 

 

CAMERA IN

 

 

 

 

 

 

 

IN X-1

 

 

 

 

 

 

 

D-sub/BNC Video Cable WJ-CA68

32 31 30

25

24

17

16

9

8

1

Video input board

Recorder

LCN: 17 to 32

Unit Address (System): 2

BNC cable

Recorder

LCN: 1 to 16

Unit Address (System): 1

Do not connect VIDEO OUT of the unit to CAMERA IN of recorders if these camera channels supply video output signals from recorders.

Note: Do not connect the VIDEO OUT ports of the unit to the CAMERA IN connectors of recorders if these camera channels supply video output signals from recorders.

Connection between Recorders and Video Input Boards

By connecting recorders to the DATA ports of this unit, recorder control becomes available from system controllers.

Recorder's unit address (System)

DATA port for recorder connection

 

 

1 to 4

DATA 3 port of Video Output Board 1

 

(Factory default: HDR1)

 

 

5 to 8

DATA 4 port of Video Output Board 1

 

(Factory default: HDR2)

 

 

9 to 12

DATA 3 port of Video Output Board 2

 

(Factory default: HDR3)

 

 

13 to 16

DATA 4 port of Video Output Board 2

 

(Factory default: HDR4)

 

 

Note: You can change data port settings according to the connected devices. Setting changes are performed in "System" – "DATA Port" of WJ-SX650 Series Administrator Console or DATA PORT (refer to p. 90) of SETUP MENU.