LOGIN AND LOGOUT

Operator Registration

Before logging into the system, operator registration is required. Operator registration is performed in "Operator" – "Operator" of WJ-SX650 Series Administrator Console. The factory default of operator information is as follows.

Operator No.

User ID

Password

Level

Priority

Camera Access

Recorder Access

 

 

 

 

 

 

 

1

650

650

1

1

View & Operate

View & Operate

 

 

 

 

 

(All cameras)

(All recorders)

 

 

 

 

 

 

 

2

1

12345

1

1

View & Operate

View & Operate

 

 

 

 

 

(All cameras)

(All recorders)

 

 

 

 

 

 

 

3

100

100

2

5

View & Operate

View & Operate

 

 

 

 

 

(All cameras)

(All recorders)

 

 

 

 

 

 

 

4

101

101

3

10

View & Operate

View & Operate

 

 

 

 

 

(All cameras)

(All recorders)

 

 

 

 

 

 

 

5

102

102

4

30

View & Operate

View & Operate

 

 

 

 

 

(All cameras)

(All recorders)

 

 

 

 

 

 

 

6

103

103

5

50

View & Operate

View & Operate

 

 

 

 

 

(All cameras)

(All recorders)

 

 

 

 

 

 

 

Operator No.: Number given for operator registration. Up to 59 operators can be registered.

User ID: ID number of operator controlling this unit. 1 to 99998 are available.

Note: Begin the entry with a numeric other than "0".

Password: For login, a password is checked as well as a User ID. Up to 5 digits are available.

Note: To protect system controllers from misuse, be sure to change the factory default passwords.

Level: An operator's restrict level. 1 to 5 are available. 1 is the highest, and 5 is the lowest.

Note: Desired functions can be assigned to each level in "Operator" – "Level Table" of WJ-SX650 Series Administrator Console.

Priority: Operator priority given to control a monitor, camera, or recorder selected by another operator. 1 to 99 are available. 1 is the highest, and 99 is the lowest.

Camera Access: View and control can be enabled or disabled for each camera.

VIEW & OPERATE: An operator can display the select- ed camera image on the selected monitor. The operator can also control the camera.

VIEW: An operator can display the selected camera image on the selected monitor, but cannot control the camera.

--:The operator can neither display the selected cam- era image on the selected monitor nor control the camera.

Recorder Access: View and control can be enabled or disabled for each recorder.

VIEW & OPERATE: An operator can display the select- ed recorder image on the selected monitor. The operator can also control the recorder.

VIEW: An operator can display the selected recorder image on the selected monitor, but cannot control the recorder.

--:The operator can neither display the selected recorder image on the selected monitor nor control the recorder.

Monitor Access: Control can be enabled or disabled for each monitor.

Notes:

Monitor Access is set for each DATA port. Operators logging into the system from the same DATA port have the common setting.

Monitor Access setting is not applied for operators logging into the system from the PC connected to the SERIAL port.

Monitor Access setting is performed in "Controller" – "Monitor Access" of WJ-SX650 Series Administrator Console.