ALARM CONTROL

Alarm Acknowledgement (ACK)

By acknowledging an alarm occurrence on an associated monitor, you can control alarm pictures.

WV-CU950/650

While a monitor in the alarm mode status is selected, press the ACK button. (During the alarm mode status, "Alarm" sign is blinking on the LCD.)

The alarm event will be acknowledged. ("Alarm" sign will change to steady light.)

WV-CU360C/CJ

While a monitor in the alarm mode status is selected, press the ACK button. (During the alarm mode status, the alarm number is blinking on the LCD.)

The alarm will be acknowledged. (The alarm number will change to steady light.)

In the ACK status, the following operations are available.

Camera Control

You can control panning/tilting of cameras, or move cam- eras to preset positions.

Alarm Picture Change

When two or more alarms are occurring, you can change alarm pictures displayed on the monitor in order or reverse order.

WV-CU950/650

To change alarm pictures on the monitor, press the + or – button. The alarm pictures will be displayed in order or reverse order.

WV-CU360C/CJ

To change alarm pictures on the monitor, press the NEXT or PREV button. The alarm pictures will be displayed in order or reverse order.

Alarm Individual Reset

You can reset each acknowledged alarm separately, and return to the status before alarm occurrence. While two or more alarms are occurring, the system will remain in the alarm mode even after an alarm reset.

To reset an acknowledged alarm, press the ACK button. The alarm will be reset.

Notes:

If the alarm event is set to OFF, an alarm will not be acknowledged. The alarm will be reset by every press- ing the ACK button.

If AUTO RESET has been set to ON, alarms will be reset automatically after the specified time. Refer to p. 86 ALARM of SETUP MENU.

Alarm Monitor Reset

You can reset all the alarms occurred to the selected moni- tor.

While the selected monitor is in the alarm mode status, press the ALM RESET*1 (or RESET*2) button. All the alarms occurred to the monitor will be reset, and the monitor dis- play will return to the status before the alarm occurrence.

*1 WV-CU950/650

*2 WV-CU360C/CJ

Note: Alarm monitor reset is also available by supplying alarm recover signals to the unit.

Alarm All Reset

You can reset all the alarms occurred to the system.

WV-CU950/650

Press the ALM ALL RESET*1 (or ALL RESET*2) button while holding down the SHIFT button. All the alarms occurred to the system will be reset.

*1 WV-CU950/650

*2 WV-CU360C/CJ