• RECORDER ALARM

Select ON or OFF to accept or not accept recorder alarm input signals.

ON: Accepts recorder alarm input signals.

OFF: Not accepts recorder alarm input signals.

• SERIAL ALARM

Select ON or OFF to accept or not accept serial alarm input signals.

ON: Accepts serial alarm input signals.

OFF: Not accepts serial alarm input signals.

• VIDEO LOSS

Select ON or OFF to accept or not accept video loss input signals.

ON: Accepts video loss input signals.

OFF: Not accepts video loss input signals.

TERMINAL ALARM Menu

330

TERMINAL ALARM

 

 

 

 

 

INPUT

BOARD=8

 

 

 

 

ALM

 

 

ALM

 

ALM

 

ALM

 

225

 

N.O.

233

N.C.

241

N.O.

249

N.C.

226

 

N.O.

234

N.C.

242

N.O.

250

N.C.

227

 

N.O.

235

N.C.

243

N.O.

251

N.C.

228

 

N.O.

236

N.C.

244

N.O.

252

N.C.

229

 

N.O.

237

N.C.

245

N.O.

253

N.C.

230

 

N.O.

238

N.C.

246

N.O.

254

N.C.

231

 

N.O.

239

N.C.

247

N.O.

255

N.C.

232

 

N.O.

240

N.C.

248

N.O.

256

N.C.

ALM=ALARM

IN

 

N.O.:NORMALLY

OPEN

 

 

 

 

 

 

N.C.:NORMALLY

CLOSE

 

 

 

 

 

 

 

 

 

• INPUT BOARD

Select a video input board from 1 to 8. (The factory default is 1.

• ALM

Select the alarm contact type for each terminal alarm input signal. (The factory default is N.O.)

N.O.: Normally Open contact

N.C.: Normally Close contact

RECORDER

You will check the settings of DATA ports to connect recorders and CAMERA IN connectors to supply video input signals from recorders. When you select RECORDER on the top menu, the following menu is displayed.

Note: Before the settings, check the system composition and refer to p. 63 Recorder Connection.

400

RECORDER

 

 

1

of

2

 

RECORDER

OUT

INPUT

BOARD8

 

 

 

RECORDER

DATA

CAM

 

 

 

 

 

 

 

01

HDR1

256

 

ON

 

 

 

 

02

HDR1

255

 

ON

 

 

 

03

HDR1

254

 

ON

 

 

 

04

HDR1

253

 

ON

 

 

 

05

HDR2

252

 

ON

 

 

 

06

HDR2

251

 

ON

 

 

 

07

HDR2

250

 

ON

 

 

 

08

HDR2

249

 

ON

 

 

DATA=DATA(TMNL/PSD/HDR)

 

 

 

 

 

 

CAM=CAMERA

IN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

400

RECORDER

 

 

2

of

2

 

RECORDER

OUT

INPUT

BOARD8

 

 

 

RECORDER

DATA

CAM

 

 

 

 

 

 

 

09

HDR3

248

 

ON

 

 

 

 

10

HDR3

247

 

ON

 

 

 

11

HDR3

246

 

ON

 

 

 

12

HDR3

245

 

ON

 

 

 

13

HDR4

244

 

ON

 

 

 

14

HDR4

243

 

ON

 

 

 

15

HDR4

 

 

OFF

 

 

 

16

HDR4

 

 

0FF

 

 

DATA=DATA(TMNL/PSD/HDR)

 

 

 

 

 

 

CAM=CAMERA

IN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• RECORDER OUT

Select the video input board or external monitor to supply video input signals from recorders.

Refer to p. 63 for connections.

INPUT BOARD1 to 8: Recorder images are displayed on monitors connected to the unit.

EXTERNAL INPUT: Recorder images are displayed on external monitors directly connected to recorders.

• RECORDER

Select the desired recorder. 1 to 16 are the recorder unit addresses. (The factory default is ON.)

ON: The recorder is used.

OFF: The recorder is not used.

• DATA

DATA ports used for the recorder connections are dis- played. DATA port setting is performed in DATA PORT. (Refer to p. 90.)

• CAM

Camera input channel numbers to supply video input sig- nals from recorders are displayed. (When RECORDER OUT is set to EXTERNAL INPUT, "- -" is displayed.)

50

Page 50
Image 50
Panasonic WJ-SX650 manual Terminal Alarm Menu, Recorder Alarm