!3VS Output Connector (VS OUT) | !4Serial Port (SERIAL) |
Supplies VS output signals to external devices. While !1 | Connects to a PC. |
is accepting a VS input signal, !3supplies an output |
|
signal synchronizing the VS input signal. While !1is not | Note: When q is set as Video Output Board 2, r, !1, |
accepting the VS input signal, !3supplies an internal | !2, !3, and !4are not available. |
synchronization output signal. |
|
■Monitor Display Information
The following are the details on terminal mode operations. For PS·Data operations, refer to p. 48 OPERATION (OTHER THAN THE TERMINAL MODE) or the operating instructions of system controllers.
q |
|
w | r |
e |
|
qTime and Date Information
Current time and date are displayed.
During daylight saving time (summer time), "∗" is dis-
played beside the time. Example: Aug/02/2005 ∗20:15:56
Note: While a recorder is being selected, time and date are not displayed.
wMonitor Status Information Monitor number
M01 to 32: Monitor number
Note: During monitor lock, monitor number is highlight- ed.
Controller number
Displays a device that selects and controls the monitor.
(Example: For
PSD: PS·Data mode system controller
PC: PC connected to the SERIAL port
/T001 to 128: Timer event
Sequence number
Displays the active sequence number.
T01 to 32: Tour sequence number
G01 to 32: Group sequence number
Note: During sequence pause, "P" is displayed beside the sequence number.
eCamera Information Camera number
C001 to 999: Camera number
R01 to 16: Recorder number
Camera title
Displays the registered camera title.
Camera title setting is performed in "Camera" – "Camera Title" of
rEvent Information
TERMINAL001 to 256: Terminal alarm has occurred. (Example: For TERMINAL001, "001" means the number of alarm input signal accepted by the ALARM IN port of video input board.)
CAMERA001 to 099: Camera alarm has occurred. (Example: For CAMERA001, "001" means the num- ber of camera supplying an alarm input signal to the unit.)
RECORDER001 to 999: Recorder alarm has occurred. (Example: For RECORDER001, "001" means the
number of camera associated with the recorder supplying an alarm input signal to the unit.)
SERIAL0001 to 1024: Serial alarm has occurred. (Example: For SERIAL0001, "0001" means the serial
command alarm input number.)
VIDEO LOSS001 to 999: Video loss has occurred.
(Example: For VIDEO LOSS001, "001" means the num-
ber of camera to which video loss has occurred) SUSPEND: Alarm is suspended.
13