SYSTEM

You will perform the system settings required to transmit data between the unit and connected devices. When you select SYSTEM on the top menu, the following menu is dis- played.

500

SYSTEM

 

 

 

510

DATA

PORTO

 

 

520

SERIAL PORT

 

 

 

BCOMMUNICATION

STATUS

38400

 

(8/

NONE/1)

 

 

530

VD2/DATA/CABLE

COMPENSATIONO

540

RS485

CAMERAO

 

 

SYSTEM Menu

• DATA PORT

DATA PORT menu will be displayed. You will select the DATA port types according to the connected devices.

• SERIAL PORT

Select the communication speed of SERIAL port. (The fac- tory default is 38 400 bps.)

4 800 bps/9 600 bps/19 200 bps/38 400 bps

Other parameters (COMMUNICATION STATUS) are as fol- lows. (Setting change is not available.)

Data bit: 8 (bits)

Parity check: NONE

Stop bit: 1 (bit)

• VD2/DATA/CABLE COMPENSATION

VD2/DATA/CABLE COMPENSATION menu is displayed. You will perform the settings for VD2, camera control signal (DATA), and cable compensation.

• RS485 CAMERA

RS485 CAMERA menu is displayed. You will set the RS-485 port numbers and unit addresses for the RS-485 cameras.

DATA PORT Menu

510 DATA PORT

 

 

 

 

 

 

DATA

TYPE

COMM.

OUT

BOARD1

1

TMNL1

 

9600

 

 

2

PSD

9600

 

 

3

HDR1

9600

 

 

4

HDR2

9600

OUT

BOARD2

5

TMNL5

9600

 

 

6

TMNL6

9600

 

 

7

HDR3

19200

 

 

8

HDR4

19200

COMMUNICATION

STATUS

8/

NONE/1

DATA=DATA(TMNL/PCD/HDR)

• TYPE

Select the DATA port types according to the connected devices.

TMNL1 to 8: Select this when using the DATA port of sys- tem controller in the terminal mode.

PSD: Select this when using the DATA port of system con- troller in the PS·Data mode.

HDR1 to 4: Select this when connecting a recorder to the DATA port.

The available port settings are as follows.

DATA1: TMNL1 /PSD (The factory default is TMNL1.)

DATA2: TMNL2 (The factory default is TMNL2.)

DATA3: TMNL3/HDR1 (The factory default is HDR1.)

DATA4: TMNL4/HDR2 (The factory default is HDR2.)

DATA5: TMNL5 (The factory default is TMNL5.)

DATA6: TMNL6 (The factory default is TMNL6.)

DATA7: TMNL7/ HDR3 (The factory default is HDR3.)

DATA8: TMNL8/ HDR4 (The factory default is HDR4.)

Note: Only one DATA port can be set to PSD.

• COMM.

Select the communication speed. (The factory default is 9 600 bps.)

4 800 bps/9 600 bps/19 200 bps

Parameters of COMMUNICATION STATUS are as follows. (Setting change is not available.)

Data bit: 8 (bits)

Parity check: NONE

Stop bit: 1 (bit)

Note: When changing the communication speed, conform the communication speed settings to that of the con- nected devices.

52