ALARM DESCRIPTIONS

Alarm Occurrence

When this unit accept an alarm input signal (terminal alarm, camera alarm, recorder alarm, serial alarm, or video loss), an alarm event (tour sequence, etc.) is activated automatically. Each alarm input signal is associated with an alarm event setting. (The setting activates the alarm input signal and alarm event.) Up to 1 024 alarm event settings are available. The alarm event setting is performed in "Alarm" – "Alarm Event" of WJ-SX650 Series Administrator Console.

By performing the settings of "Alarm Event", the following events will be activated when this unit accepts an alarm input signal.

Alarm event information will be displayed on the associated monitors (Refer to p. 16 Monitor Display Information.)

Depending on the setting of "Display Mode", camera images will be displayed, or sequences will be activated on the asso- ciated monitors. In this document, these actions are mentioned as the alarm mode, and pictures displayed during the alarm mode is mentioned as alarm pictures.

If a recorder is selected for "Recording Source LCN", event recording will be activated. (Recording will follow the command alarm setting and event recording setting of recorder. Refer to the operating instructions of recorder for details.)

If an alarm output terminal is selected for "Alarm Output", alarm output signal will be supplied from the video output board. The associated recorder can be notified of the alarm occurrence, and external alarm devices (buzzer, etc.) can be activat- ed.

Notes:

To activate terminal alarm output signals, perform settings of No.1 to 64. No.65 and greater are assigned for serial commands.

To activate serial alarm output signals, serial command settings are required. The settings are performed in "Communication" – "Serial Command" of WJ-SX650 Series Administrator Console.

ALARM indicators of all system controllers blink.

Up to 10 000 alarm records are saved chronologically. The latest 1 000 alarm records can be displayed as the alarm his- tory on the monitor. (Refer to p. 33 Alarm History Display.) The Alarm History Display can be downloaded from the PC to the unit.

Alarm information is notified to the PC in serial commands. The serial command setting is performed in "Communication" – "Serial Command" of WJ-SX650 Series Administrator Console.

Camera 100

This unit Alarm Output 50

 

Preset Position 1

 

(Zooming in No.1 (Entrance))

650

Terminal Alarm

 

256

Monitor 5

No.1 (Entrance)

 

Alarm input signal from a sensor

Records the image of Camera 10. (Recording follows the command alarm setting and event recording setting of recorder.)

1

2

3

4

5

6

7

8

9

10/0

11

12

13

14

15

16

Recorder 10

Notifies the

PC

alarm event

occurrence.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Alarm Input 256

 

 

 

 

 

 

Sensor

 

 

 

 

 

 

system

 

 

 

 

Infrared sensor

 

 

 

 

Terminal alarm setting

 

 

 

 

 

No.

Display Mode

Spot

 

Monitor

Recording

Alarm Output

LCN

Preset

Source (LCN)

 

 

 

 

 

 

 

 

 

256

SPOT

100

1

5

10

50

66

Page 66
Image 66