■WJ-SX650 Series Administrator Console
Problem
"!" mark is displayed in the LCN entry field.
"!" mark is displayed in the
Cannot set Control to ON in "System" – "Recorder".
Cannot set the
An error message appears when changing the monitor setting in "Sequence" – "Group Sequence", and click- ing "Set".
"!" mark (in a circle) is dis- played in the list of "Schedule" – "Timer Event".
"!" mark (in a triangle) is dis- played in the list of "Schedule" – "Timer Event".
"Monitor Display Mode parame- ter in "Monitor Display Mode" of "Alarm" – "Alarm Event" is dis- played in gray, and you cannot change the parameter.
Cannot click a checkbox to activate Auto Login and Auto Logout in "Controller" – "Auto Login/Auto Logout".
Check item and remedy
•Check if the camera number not registered is set for the cam- era position, tour sequence, group sequence, timer event, alarm event, recorder, or camera input channel. Register the camera number in "System" – "Logical Camera Number".
•Check if the camera position number not registered is set for the tour sequence, group sequence, timer event, or alarm event. Register the camera position number in "Camera" – "Camera Position".
•Check if the camera input channel connected to the recorder is set
•Check if Control is set to ON for the recorder connected to the camera input channel in "System" – "Recorder". Set OFF for the recorder.
•Check if the group sequence is associated with an alarm event. You cannot change the monitor settings of group sequences associated with alarm events. Delete alarm event settings with which the group sequence is associated.
Check if the camera number or camera position number not registered is set for the event.
•Register the camera number in "System" – "Logical Camera Number".
•Register the camera position number in "Camera" – "Camera Position".
•Start time of event is set for the period during which an event with higher priority has been set. Change the settings of start time and priority of the event.
•Check if the monitor is associated with an alarm event. You cannot change the monitor display modes of monitors associ- ated with alarm events. Delete alarm event settings for which the monitor is assigned.
•Check if the DATA port is set to PSD or HDR in "System" – "DATA Port".
You cannot set auto login and auto logout for DATA ports set to PSD or HDR. Set the DATA port to TMNL.
Reference
–
–
–
–
29
–
–
29
–
93