Alarm Modes

The following alarm modes are available. (Alarm mode fol- lows the setting of "Display Mode".)

Spot

The image of associated camera will be displayed on the monitor. Preset position or auxiliary control will be activated. The following alarm modes (=patterns to display alarm pic- tures on a monitor) are available. (Regardless of alarm modes, alarms occur to all the associated cameras.) The alarm mode setting is performed in "Alarm" – "Alarm Mode" of WJ-SX650 Series Administrator Console or "ALARM" of

SETUP MENU.

• Sequence mode

Alarm pictures are sequentially displayed on the associated monitor.

Alarm 1

Alarm 2

Alarm 3

Alarm 4

• Earliest mode

The earliest alarm picture is displayed on the associated monitor.

Alarm 1

• Latest mode

The latest alarm picture is displayed on the associated monitor.

Alarm 4

Tour Sequence

Tour sequence is activated on the associated monitor.

Group Sequence/Preset

Group sequence is activated on the associated monitors.

OFF

Alarm information is displayed on the associated monitor, but alarm does not occur to monitors and cameras.

Notes:

When a tour sequence, group sequence, or group pre- set is activated as an alarm event, the earlier alarm event on the monitor will be reset.

When 33 or more alarms occur to a monitor, older alarms will be reset chronologically.

After occurrence, the same alarm will be suspended for 5 seconds.

By the alarm schedule setting, alarm events can be deactivated in the specified periods. The alarm sched- ule setting is performed in "Alarm" – "Alarm Event" of WJ-SX650 Series Administrator Console.

Video Loss

To display the video loss information on associated moni- tors and save the video loss history without making alarms occur to monitors and cameras, set "Display Mode" to OFF. Note: If Alarm A ("Display Mode" is OFF) occurs while Alarm B's ("Display Mode" is Spot, Tour Sequence or Group Sequence) are being activated, the Alarm A information will be displayed on the monitor after all

Alarm B's have been reset.

67

Page 67
Image 67
Panasonic WJ-SX650 manual Alarm Modes, Video Loss, Spot, Group Sequence/Preset