Model 3830 AT Commands

Xn Extended Result Code,Dial Tone Detect,and Busy Tone Detect The Xn command sets three configuration options simultaneously:

 

Ext

Dial Tone

Busy Tone

 

Result Code

Detect

Detect

 

 

 

 

X0

Disable

Disable

Disable

X1

Enable

Disable

Disable

X2

Enable

Enable

Disable

X3

Enable

Disable

Enable

X4

Enable

Enable

Enable

X5

Add/EC

Enable

Enable

X6

Add/V42,MNP

Enable

Enable

X7

Use DTE Rate

Enable

Enable

 

 

 

 

EXTENDED RESULT CODE

Informational messages such as VF (line) connect rate and Error Control are displayed with the result codes.

Disable. Displays basic result codes: OK, CONNECT, RING, NO CARRIER, and ERROR.

Enable. Displays basic result codes in addition to the CONNECT rate message (for example, CONNECT 14400).

Add/EC. If error control is negotiated, attaches the /EC suffix to the CONNECT rate message.

Add/V42,MNP. Attaches the V42b, V42, MNP5, MNP4, MNP3, MNP2, or NoEC suffixes to the CONNECT rate message.

Use DTE Rate. Displays DTE data rate instead of line CONNECT rate message.

DIAL TONE DETECT

Sets the modem for dial tone detection (enable) or blind dialing (disable).

Disable. Sets the modem for blind dialing.

Enable. Sets the modem for dial tone detect.