4. AT Command Set and S-Registers

Table 4-3

(6 of 20)

Model 3830 S-Registers

S37 Auto Redial

Works in conjunction with the Bad Lines Auto Originate and Rate Auto Originate options. It allows repeated automatic dial backup attempts by specifying the range of Directory Locations that can be tried. The modem must be in Originate mode.

Register has the following values:

0 = Use Directory Location 1

1 = Use Directory Locations 1±2

2 = Use Directory Locations 1±3

3 = Use Directory Locations 1±4

DD D

DD D

9 = Use Directory Locations 1±10

NOTE: The modem must be in Originate mode to perform an automatic dial backup.

S38 DTR Cont Repeat

Determines whether automatic dialing of dial backup directory locations will be repeated continuously, or halted after the first pass.

Regardless of the setting of S38, dialing is locked out after ten failed attempts to connect to the same number.

Register has the following values:

0 = Disable

1 = Enable

Factory setting is Disable.

3830-A2-GB91-30

August 1998

4-35

Page 71
Image 71