Paradyne 3830 manual Call Failure Indication CFI, Call Connecting CNX

Models: 3830

1 138
Download 138 pages 42.35 Kb
Page 108
Image 108

COMSPHERE 3800 Series Modems ± Model 3830

Call Failure Indication (CFI)

The CFI response is issued to the DTE if the modem fails a CRN or CRS command. CFI is similar to the AT result codes BUSY, NO ANSWER, NO CARRIER, NO DIALTONE, and ERROR.

The CFI response format is:

CFIxx

Where: xx is

ET Engaged tone

NS Number not stored

CB Local DCE busy

RT Time-out on ring tone

AB Abort call on time-out

NT Answer tone not detected

FC Forbidden call

ET is similar to the Call Failure Messages Busy Signal and Trunk Busy and the result code BUSY.

NS is similar to the Common Operational Message Invalid Number and the result code ERROR.

CB is similar to the Call Failure Messages Dial Line in Use and No Dial-Test and the result code ERROR.

RT is similar to the Call Failure Message No Answer Tone and the result code NO CARRIER.

AB is similar to the Call Failure Messages No Dial Tone and No Dial-DTR and the result code NO DIALTONE and ERROR.

NT is similar to the Call Failure Message No Quiet Answer and the result code NO ANSWER.

Call Connecting (CNX)

The CNX response informs the DTE that the modem has connected to the remote modem. CNX is similar to the AT result code CONNECT.

The CNX response format is CNX.

D-4

August 1998

3830-A2-GB91-30

Page 108