COMSPHERE 3800 Series Modems ± Model 3830
Table
(22 of 23)
Model 3830 AT Commands
%Bn Modulation and Data Rate
Sets the modulation and maximum VF rate.
The %B300 and %B1200 commands work in conjunction with the B
%B19200 | V.32terbo, maximum rate 19,200 bps |
%B16800 | V.32terbo, maximum rate 16,800 bps |
%B14400 | V.32bis, maximum rate 14,400 bps |
%B12000 | V.32bis, maximum rate 12,000 bps |
%B9600 | V.32bis/V.32, maximum rate 9600 bps |
%B7200 | V.32bis, maximum rate 7200 bps |
%B4800 | V.32bis/V.32, maximum rate 4800 bps |
%B2400 | V.22bis. maximum rate 2400 bps |
%B1200 | V.22 or Bell 212A, maximum rate 1200 bps |
%B300 | V.21 or Bell 103, maximum rate 300 bps |
Modulation and Data Rate can also be set using
S41 | = 20 | %B19200 | V.32terbo, 19,200 bps |
S41 | = 21 | %B16800 | V.32terbo, 16,800 bps |
S41 | = 1 | %B14400 | V.32bis, 14,400 bps |
S41 | = 2 | %B12000 | V.32bis, 12,000 bps |
S41 | = 3 | %B9600 | V.32bis/V.32, 9600 bps |
S41 | = 4 | %B7200 | V.32bis, 7200 bps |
S41 | = 5 | %B4800 | V.32bis/V.32, 4800 bps |
S41 | = 6 | %B2400 | V.22bis. 2400 bps |
S41 | = 7 | %B1200/B0 | V.22, 1200 bps |
S41 | = 8 | %B1200/B1 | Bell 212A, 1200 bps |
S41 | = 10 | %B300/B0 | V.21, 300 bps |
S41 | = 11 | %B300/B1 | Bell 103J, 300 bps |
The factory default is %B19200.
August 1998 |