COMSPHERE 3800 Series Modems ± Model 3830
Table
(7 of 20)
Model 3830 S-Registers
S39 Receive Buffer Disconnect Delay
Determines the maximum amount of time the modem can continue to send data in its Receive Buffer to the DTE after the modem is commanded by the DTE to disconnect, or after the modem detects a line disconnect.
Register has the following values:
0 = Disable (Immediate disconnect)
1 = 1 second
2 = 2 seconds
D | D | |
D | D |
255 = 255 seconds
S41 Dial-Line Rate
Determines the modem's highest data rate and modulation scheme for operation on dial lines.
Register has the following values:
1 = 14,400 (V.32bis)
2 = 12,000 (V.32bis)
3 = 9600 (V.32bis/V.32)
4 = 7200 (V.32bis)
5 = 4800 (V.32bis/V.32)
6 = 2400 (V.22bis)
7 = 1200 (V.22)
8 = 1200 (212A)
10 = 0±300 (V21)
11 = 0±300 (103J)
12 = 1200/75 (V.23)
13 = 75/1200 (V.23)
20 = 19,200 (V.32terbo)
21 = 16,800 (V.32terbo)
Factory setting is 19,200 (V.32terbo).
August 1998 |