4. AT Command Set and S-Registers

Table 4-3

(10 of 20)

Model 3830 S-Registers

S48 Leased Line Carrier On Level

Determines if the modem disconnects if the carrier signal on leased lines falls below ±26 dBm or ±43 dBm.

Register has the following values: 0 = ±43 dBm

1 = ±26 dBm

Factory setting is ±43 dBm.

S49 Transmit Buffer Disconnect Delay

Determines the maximum amount of time the modem can continue to send data in its Transmit Buffer to the remote modem after it is commanded by the DTE to disconnect.

Register has the following values:

0 = Disable (Immediate disconnect)

1 = 1 second

2 = 2 seconds

DD

DD

255 = 255 seconds

Factory default is 10 seconds.

S51 DTE Remote Loopback (CT140)

Determines if the modem performs a remote digital loopback if it receives a CT140 signal from the DTE.

Register has the following values:

0 = Disable

1 = Enable

Factory setting is Disable.