4. AT Command Set and S-Registers

Table 4-2

(11 of 23)

Model 3830 AT Commands

&In Dial Transmit Level for Cellular Auto

When Dial Transmit Level Type is set to Permissive, &In sets Dial Transmit Level to a value between ±10 and ±32 dBm. If Enhanced Throughput Cellular (ETC) is installed, &I99 and &I100 causes the level to be varied automatically according to conditions for ETC operation. &J0 overrides this command.

&I10 ±10 dBm &I11 ±11 dBm

DD

DD

&I32 ±32 dBm

&I99 Valid only if ETC is installed. Dial Transmit Level is automatically adjusted according to the ETC1.0 specification. Use only with remote modems set to &I99, and limit the data rate to 4800 bps (S41=5).

&I100 Valid only if ETC is installed. Dial Transmit Level is automatically adjusted according to the ETC1.1 specification. Set by &F6.

&Jn Dial Transmit Type

Sets the power output level of the transmit signal over dial lines. &Jn overrides the &In command.

&J0 Permissive (±9 dBm)

&Ln Leased Mode

Sets the modem for 2-wire leased-line operation in Answer mode (receiving a call) or in Originate (initiating a call) mode.

&L0 Disables leased-line operation.

&L1 2-wire originate leased-line operation. &L3 2-wire answer leased-line operation.

The &L command will cause the modem to reset before entering or exiting Leased-Line mode. Therefore, it must be entered as the last command in an initialization string.